Input/output blocks
1-4
Function Blocks - FM 458-1 DP
Edition 12.2004
Value
Significance
Nibble 1
0x0001 Initialization
mode
0x0002
No SBM2 module available
0x0004
SBM2 module is processed from another SBM
0x0008
Encoder defective/not available
Nibble 2
0x0010
Unknown carrier or illegal module code
0x0020
Incorrect hardware address
0x0040
Encoder fault/error
→
Check the hardware (encoder, cable etc.)
0x0080
No voltage or short-circuit
Nibble 3
0x0100
No data transfer from or to the encoder
→
check the hardware (encoder, cable etc.)
0x0200
Erroneous data transfer from or to the encoder
→
check the hardware (encoder, cable etc.)
0x0400
Invalid mode parameterized
0x0800
Invalid encoder parameterized
Nibble 4
0x1000
Invalid speed normalization parameterized
0x2000
Invalid baud rate parameterized
0x4000
Sampling time too high; speed computation not possible
→
Sampling time:
≤
4.0 ms
0x8000
Error for the request to save
Nibble 5
0x10000
Invalid resolution parameterized
0x20000
Function block is not configured in the alarm task
0x40000
Not defined: Reserve
→
Default: 0
0x80000
Not defined: Reserve
→
Default: 0
Nibble 6-8
Not defined: Reserve
→
Default: 0
Computation time [µs]
FM 458-1 DP
13,2
Can be inserted online
No
Can be configured in
Interrupt tasks
Cyclic tasks
Executed in
Initialization mode
Normal mode
Special features
Can only be used with an EQN 1325 encoder
Error statuses
Configuringdata