Details for ordering

Key DMZ1195

3

13 | 18

Building Technologies

A6V10425648_en--_f

Fire Safety

2016-11-28

3.4 Key DMZ1195

For opening doors on manual call points
Compatible with:
– Radio manual call point FDM273-O
Order number: BPZ:4851910001

3.5 Glass insert DMZ1196-AC

For alarm activation and protection against

soiling
Compatible with:
– Radio manual call point FDM273-O
Order number: BPZ:4942050001

3.6 Protective cover DMZ1197-AC

For protection against unintended alarm

activation
Compatible with:
– Radio manual call point FDM273-O
Order number: BPZ:5223550001

3.7 Window sign

For inserting in manual call point
Printed on both sides:
– Front: 'Fire brigade'
– Back: 'Fire detector'
Only for Germany
Compatible with:
– Manual call point FDM273-O
Order number: BPZ:5304150001

Содержание FDM273

Страница 1: ...FDM273 O Radio manual call point Mounting A6V10425648_en _f Building Technologies 2016 11 28 Control Products and Systems ...

Страница 2: ... communication thereof to others without express authorization are prohibited Offenders will be held liable for payment of damages All rights created by patent grant or registration of a utility model or design patent are reserved Issued by Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 CH 6301 Zug Tel 41 41 724 2424 www siemens com buildingtechno...

Страница 3: ...ling the protective cover 10 2 5 Inserting the door sign 11 3 Details for ordering 12 3 1 Switching unit FDME273 O 12 3 2 Housing FDMH273 R 12 3 3 Battery pack BAT3 6 10 12 3 4 Key DMZ1195 13 3 5 Glass insert DMZ1196 AC 13 3 6 Protective cover DMZ1197 AC 13 3 7 Window sign 13 4 Specifications 14 4 1 Technical data 14 4 2 Dimensions 16 4 3 Master gauge for recesses 16 4 4 Environmental compatibilit...

Страница 4: ...Building Technologies A6V10425648_en _f Fire Safety 2016 11 28 4 18 ...

Страница 5: ... been established Mounting should be performed by a specialist in compliance with safety regulations Intended use The radio manual call point FDM273 O may only be used in a fire detection system with a radio gateway approved by the manufacturer The radio manual call point FDM273 O is compatible with the radio module FDRF272 O You will find more information on the radio fire detector in document A6...

Страница 6: ...nd battery pack to hand w You have a tool and two screws for securing purposes The screws have a Ø 2 5 3 mm shaft and a Ø 8 mm head surface 1 Push the keyhole cover to the right 2 Open the door with the key supplied 3 NOTICE Keep the key in a safe place 4 Push the keyhole cover back into place 5 For securing purposes select two screw positions that are spaced far apart from one another Use screw p...

Страница 7: ... Fire Safety 2016 11 28 2 2 Installing the housing Figure 2 Example of securing onto the substructure using two screws w The housing is ready for mounting See the chapter Preparation l Screw the housing securely onto the substructure using two screws a The housing has been installed 8 mm 2 5 3 mm ...

Страница 8: ...ed in the scope of delivery The flashing behavior of the internal alarm indicator is described in document A6V10425645 in the Internal alarm indicator chapter w The housing has been installed w The radio gateway has been activated and switched to maintenance mode w The battery pack and switching unit are available w The switching unit is set to the factory settings w The door 5 is open w The alarm...

Страница 9: ... this indicates that the radio manual call point has already been logged on to a radio gateway a If this does not happen this means the battery pack is defective and must not be used 6 Insert the battery pack into the switching unit FDME273 O so that it snaps into place in the holders 7 7 Insert the switching unit with the battery pack into the housing paying attention to the position of the batte...

Страница 10: ...acing the glass insert 3 Guide the protective cover 1 through the opening in the door from the front as shown in the diagram 4 Insert the pivot pins 2 for the protective cover 1 in the two recesses on the rear side of the door as shown in the diagram 5 Install the glass insert See the chapter Replacing the glass insert 6 Close the door of the manual call point a The protective cover is inserted Fi...

Страница 11: ...ulations require the manual call point to be labeled in this way w The appropriate door sign printed on both sides is available 1 Open the door and lift the transparent cover to the side 2 Insert the door sign so the desired side is displayed 3 Attach the transparent cover so that it snaps into place at the side a The manual call point has a new label Figure 5 Mounting the door sign ...

Страница 12: ...273 R For the OEM radio fire detection system Holds a switching unit FDME273 O Order number S54323 B109 A1 3 3 Battery pack BAT3 6 10 For supplying radio devices and the radio gateway with power Lithium batteries BAT3 6 10 LI SOCl2 battery pack 3 6 V 10 Ah Batteries with battery cable Connector system with protection against polarity reversal Inscription field for commissioning date Compatible wit...

Страница 13: ...activation and protection against soiling Compatible with Radio manual call point FDM273 O Order number BPZ 4942050001 3 6 Protective cover DMZ1197 AC For protection against unintended alarm activation Compatible with Radio manual call point FDM273 O Order number BPZ 5223550001 3 7 Window sign For inserting in manual call point Printed on both sides Front Fire brigade Back Fire detector Only for G...

Страница 14: ... 868 MHz band 20 in 433 MHz band Transmitting power 10 mW ERP in band 44b 45b and 49 Type 10 max 25 mW ERP in band 48 50 54b and 56b Range See document A6V10425603 2013 752 EU according Official Journal of the European Union COMMISSION IMPLEMENTING DECISION of 11 December 2013 amending Decision 2006 771 EC on harmonisation of the radio spectrum for use by short range devices and repealing Decision...

Страница 15: ...75 C Air humidity 95 rel Protection categories in accordance with IEC 60529 FDM273 O Housing FDMH273 R IP44 Electromagnetic compatibility 10 kHz 100 kHz 100 kHz 2 5 GHz 160 V m 30 V m Mechanical data Weight FDMH273 R FDME273 O 0 279 kg 0 098 kg Housing material FDMH273 R Polycarbonate PC Colors FDMH273 R RAL 3000 flame red Standards European standards EN 54 11 EN 54 25 EN 300220 2 EN 301489 3 EN 6...

Страница 16: ...ding Technologies A6V10425648_en _f Fire Safety 2016 11 28 4 2 Dimensions Radio manual call point FDM273 O 4 3 Master gauge for recesses Radio manual call point FDM273 O 134 4 32 31 2 35 6 14 21 6 27 8 61 8 37 4 8 43 4 67 24 61 5 37 5 25 11 ...

Страница 17: ...asures have been undertaken Use of reusable materials Use of halogen free plastics Electronic parts and synthetic materials can be separated Larger plastic parts are labeled according to ISO 11469 and ISO 1043 The plastics can be separated and recycled on this basis Electronic parts and batteries must not be disposed of with domestic waste Take electronic parts and batteries to local collection po...

Страница 18: ...al Headquarters Gubelstrasse 22 CH 6301 Zug 41 41 724 24 24 www siemens com buildingtechnologies Siemens Switzerland Ltd 2014 Technical specifications and availability subject to change without notice Document ID A6V10425648_en _f Manual FD20 FD720 Edition 2016 11 28 Register 3 ...

Отзывы: