Connecting the pipes

Note: 

If using an aluminium pipe, smooth the connection area 

beforehand.

Exhaust-air pipe Ø 150 mm (recommended size)

Attach exhaust-air pipe directly to the air-pipe connector 
and seal.

Exhaust-air pipe Ø 120 mm

1.

Attach reducing connector directly to the air-pipe connector.

2.

Attach exhaust air pipe to the reducing connector. 

3.

Seal both joints appropriately.

Electrical connection

ã=

Risk of electric shock!

from damaged connection cable. Do not kink or pinch 
connection cable during installation.

The required connection data can be found on the rating plate 
inside the appliance; to do this, remove the metal-mesh grease 
filter.

Length of the connection cable: approx. 1.30 m

This appliance complies with the EC interference suppression 
regulations.

This appliance may be connected to a correctly installed 
earthed socket only.

Attach the earthed socket preferably inside the flue duct.

The earthed socket should be connected via its own circuit.

If the earthed socket is no longer accessible following 
installation of the appliance, a disconnector must be fitted 
as for a permanent connection. 

If a permanent connection is required, the installation must 
feature an all-pole disconnector (circuit breakers, fuses 
and contactors) with a min. 3 mm contact opening. 
The permanent connection may be installed by an electrician 
only.

Attaching flue duct

ã=

Risk of injury!

From sharp edges during installation. Always wear protective 
gloves while installing the appliance.

1.

Separate the flue ducts. 
To do this, remove the adhesive tape.

2.

Remove the protective foil from both flue ducts.

3.

Push one flue duct into the other.

Notes

To prevent scratches, place paper for protection over 
the edges of the outer flue duct.

– Slots of the inner flue duct downwards.

4.

Place flue ducts on the appliance.

5.

Push inner flue duct upwards and attach to the fixing 
brackets on the left and right. 

¨

6.

Press flue duct downwards until it engages. 

©

7.

Screw flue duct to the sides of the fixing bracket using two 
screws. 

ª

PLQ

PP

PLQ

PP

PLQPP

PD[PP

$

%

&

Содержание Extractor hood

Страница 1: ... en Instructions for installation and use Extractor hood ...

Страница 2: ...Danger of suffocation from packaging material Never allow children to play with packaging material After unpacking the appliance check it for visible damage Do not connect the appliance if it has been damaged in transit These instructions apply to several appliance models It is possible that individual features are described which do not apply to your appliance Adults and children must never use t...

Страница 3: ...cable Do not kink or pinch connection cable during installation Risk of fire risk of injury from damaged connection cable A damaged connection cable must be replaced by a qualified technician electrician Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance Risk of injury from a falling appliance All safety screws and safety caps must be f...

Страница 4: ... activated carbon filter The different options of operating the appliance in circulating air mode can be found in the brochure or ask your dealer The required accessories are available from specialist outlets from customer service or from the Online Shop The accessory numbers can be found at the end of the instructions for use Operation These instructions apply to several appliance models It is po...

Страница 5: ...om the Online Shop see front of the instructions for use Note The appliance surface and controls are scratch sensitive Observe the warranty regulations in the enclosed service booklet and the following cleaning instructions Clean the surfaces with a soft damp cloth washing up liquid or a mild window cleaner Soften dried dirt with a damp cloth Do not scratch Dry cloths abrasive sponges scouring age...

Страница 6: ...grease filter Replacing halogen bulbs Note When inserting halogen bulbs do not touch the glass tube Use a clean cloth to insert the halogen bulbs 1 Carefully remove bulb ring using a suitable tool 2 Pull out bulb and replace with bulb of the same type 3 Insert bulb cover 4 Insert mains plug or switch on fuse again LED lights Defective LED lights may be replaced by the manufacturer his customer ser...

Страница 7: ...ways be ensured An incoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa 0 04 mbar This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhau...

Страница 8: ...Ø 120 mm approx 113 cm2 Flat ducts should have no sharp deflections Use sealing strip for deviating pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the boreholes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for...

Страница 9: ...ation remove foil completely 2 When attaching the appliance ensure that it engages firmly with the brackets 3 Align the appliance horizontally by turning the brackets If required the appliance can be moved to the right or left Securing the appliance 1 Press the safety caps with the arrow upwards onto the brackets until they engage 2 Screw on knurled nut and washer firmly Removing safety caps If th...

Страница 10: ...thed socket should be connected via its own circuit If the earthed socket is no longer accessible following installation of the appliance a disconnector must be fitted as for a permanent connection If a permanent connection is required the installation must feature an all pole disconnector circuit breakers fuses and contactors with a min 3 mm contact opening The permanent connection may be install...

Страница 11: ...11 ...

Страница 12: ...Siemens Electrogeräte GmbH Carl Wery Straße 34 81739 München Germany 9000550704 9000550704 900731 ...