11.9 Mode 10 Data
11.9.1 Modulator to CCB
Mode 10 is dedicated to collecting diagnostic information from the CCB and is also used for issuing ‘Cell Fault
Reset’ commands by setting bit 2 high (‘1’).
Table 11-9: Mode 10 Modulator to CCB Data
11.9.2 CCB to Modulator
The response data for Mode 10 is shown below where bits 2 through 6 indicate a fault condition when set low (‘0’).
Table 11-10: Mode 10 Data from Power Cell to Modulator
Bit
Description
0
0 -> Mode definition bit
1
1 -> Mode definition bit 1
2
Cell Fault Reset
3
0 (not used)
4
0 (not used)
5
0 (not used)
6
Sync pulse for temperature engine
7
Odd Parity Bit
Bit
Description
0
0 -> Mode definition bit 0
1
1 -> Mode definition bit 1
2
Not Q1 Out of Saturation (OOS) Fault
3
Not Q2 Out of Saturation (OOS) Fault
4
Not Q3 Out of Saturation (OOS) Fault
5
Not Q4 Out of Saturation (OOS) Fault
6
Cell Output Fuse (OK)
7
Odd Parity Bit
Содержание Eupec
Страница 10: ...Safety Precautions and Warnings MicroHarmony Cell Sizes 40 260A Manual viii 19001467 Version 1 0 s ...
Страница 16: ...Cell Overview MicroHarmony Cell Sizes 40 260A Manual 1 6 19001467 Version 1 0 s 1 ...
Страница 36: ...Installation MicroHarmony Cell Sizes 40 260A Manual 3 4 19001467 Version 1 0 s 3 ...
Страница 42: ...Electrical Description MicroHarmony Cell Sizes 40 260A Manual 4 6 19001467 Version 1 0 s 4 ...
Страница 56: ...Repair Hints MicroHarmony Cell Sizes 40 260A Manual 8 4 19001467 Version 1 0 s 8 ...
Страница 76: ...Drive Calc Express MicroHarmony Cell Sizes 40 260A Manual 10 2 19001467 Version 1 0 s 10 ...
Страница 86: ...Communication Protocol MicroHarmony Cell Sizes 40 260A Manual 11 10 19001467 Version 1 0 s 11 ...
Страница 87: ...MicroHarmony Cell Sizes 40 260A Manual NOTES 19001467 Version 1 0 N 1 s NOTES ...
Страница 88: ...NOTES MicroHarmony Cell Sizes 40 260A Manual N 2 19001467 Version 1 0 s ...
Страница 89: ...MicroHarmony Cell Sizes 40 260A Manual NOTES 19001467 Version 1 0 N 3 s ...
Страница 90: ...NOTES MicroHarmony Cell Sizes 40 260A Manual N 4 19001467 Version 1 0 s ...