1 Introduction
This manual describes the procedure for using the ERTEC 200 for HW development of a PROFINET IO device and
the properties of the EB 200 evaluation board.
The intended use of the EB 200 evaluation board is as follows:
It serves as a template for development of your own PROFINET IO device hardware.
It supports development and testing of your own PROFINET IO device application software.
It enables testing of your hardware on a supplementary board together with the EB 200, where applicable.
1.1 Procedure when Using ERTEC 200 to Develop Your Own PROFINET IO Device
The "DK-ERTEC200 PN IO" CD contains two circuit diagrams:
1. Circuit diagram of the EB 200
EB200 circuit diagrams.pdf
2. Minimum configuration for a PROFINET IO device
EB200 AN001 minimal circuit configuration.pdf
If you are using the recommended minimum configuration for a PROFINET IO device, no changes (or only minor
changes) have to be made in the board support package (BSP) for your additionally required hardware. The board
support package adapts the operating system to the hardware, see /3/.
Procedure
You can use ERTEC 200 to develop your own hardware in one of two ways:
o
By using a test board on the EB 200 to adapt and test your application circuit
o
By using ERTEC 200 directly to develop and test your complete target hardware
Note the following boundary conditions for hardware development:
Minimum Memory Capacity
Memory Type
Minimum
Recommended
Flash AMD29DL323GB-90EI/T AMD
4 Mbytes
4 Mbytes
SDRAM HYP39S25616DT-7.5 Infineon
32 Mbytes
64 Mbytes
Debug Interfaces for Commissioning and Testing
Always
make provision for connectors on your hardware to the JTAG interface and, if possible, to a serial interface
(UART1) of the ERTEC 200 in order to facilitate commissioning.
Copyright © Siemens AG 2010. All rights reserved.
8
EB 200 Manual
Technical data subject to change