Description:
Timer MUX Register Event2 Select
Bit
Identifier
Reset
Attr.
Function / Description
3dt0 TIM0_EVENT2_SEL_3_0
0h
r w
Selection of
EXTERNAL_INPUTS(15:0) for
EXT_Event 2 of Timer 0
7dt4 TIM1_EVENT2_SEL_3_0
0h
r w
Selection of
EXTERNAL_INPUTS(15:0) for
EXT_Event 2 of Timer 1
11dt8 TIM2_EVENT2_SEL_3_0
0h
r w
Selection of
EXTERNAL_INPUTS(15:0) for
EXT_Event 2 of Timer 2
15dt12 TIM3_EVENT2_SEL_3_0
0h
r w
Selection of
EXTERNAL_INPUTS(15:0) for
EXT_Event 2 of Timer 3
19dt16 TIM4_EVENT2_SEL_3_0
0h
r w
Selection of
EXTERNAL_INPUTS(15:0) for
EXT_Event 2 of Timer 4
23dt20 TIM5_EVENT2_SEL_3_0
0h
r w
Selection of
EXTERNAL_INPUTS(15:0) for
EXT_Event 2 of Timer 5
31dt24 <reserved>
00h
not used
Register:
SW_EVENT_TRIGGER_REG
Address:
D4h
Bits:
31dt0
Reset value:
00000000h
Attributes: (w)
Description:
Timer SW Event Register
Bit
Identifier
Reset
Attr.
Function / Description
5dt0 SW_EVENT_TRIG5_0
00h
w
Software Event for Saving Counter
value in Int_Event register of Timer
5...0
1: Software event active, read
=always 0
31dt6 <reserved>
0000000h not used
2.3.10.4
F-Counter
For F-applications, another timer not dependant on the system clock is required in addi-
tion to a system timer. The functionality corresponds to the F-counter function of the IBC
blocks.