Operating modes

This appliance can be used in exhaust-air mode or circulating-

air mode.

Exhaust air mode

Note: 

The exhaust air must not be conveyed into a functioning 

smoke or exhaust gas flue or into a shaft which is used to 

ventilate installation rooms which contain heating appliances.

Before conveying the exhaust air into a non-functioning 

smoke or exhaust gas flue, obtain the consent of the heating 

engineer responsible.

If the exhaust air is conveyed through the outer wall, a 

telescopic wall box should be used.

Air recirculation

Note: 

To bind odours in air recirculation mode, you must install 

an activated carbon filter. The different options for operating the 

appliance in air recirculation mode can be found in the 

brochure. Alternatively, ask your dealer. The required 

accessories are available from specialist retailers, from 

customer service or from the Online Shop.

Getting to know the appliance

Here, you can get to know your appliance and receive 

information about the accessories.

Control panel

The air which is drawn in is cleaned by the 

grease filters and conveyed to the exterior by a 

pipe system.

The air which is drawn in is cleaned by the 

grease filters and an activated carbon filter, 

and is conveyed back into the kitchen.

1

Control panel

2

Light

3

Filter cover

Explanation

#

Retract/extend the appliance, switch the fan on and off

1

Switches on fan level 1

2

Switches on fan level 2 

3

Switches on fan level 3 

4/

G

Switches on fan level 4 or intensive mode

H

Switches on interval ventilation

y

Switches on the fan run-on

B

Switches on the lighting

Содержание DDA097G59

Страница 1: ...Instruction manual Extractor hood DDA097G59 DDA097G59B ...

Страница 2: ......

Страница 3: ...ectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level...

Страница 4: ...o assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filter Risk of fire ...

Страница 5: ... damage due to ingress of humidity into the electronic circuitry Never clean operator controls with a wet cloth Surface damage due to incorrect cleaning Clean stainless steel surfaces in the direction of the grain only Do not use any stainless steel cleaners for operator controls Surface damage due to strong or abrasive cleaning agents Never use strong and abrasive cleaning agents Items placed on ...

Страница 6: ... air recirculation mode can be found in the brochure Alternatively ask your dealer The required accessories are available from specialist retailers from customer service or from the Online Shop Getting to know the appliance Here you can get to know your appliance and receive information about the accessories Control panel The air which is drawn in is cleaned by the grease filters and conveyed to t...

Страница 7: ...e set fan level lights up Switching off Press the button Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours 1 Press and hold the 4 G button while the ventilation system is switched on The 4 G button flashes once per second Intensive mode is activated 2 Press the 4 G or button Intensive mode is deactivated Note The run time of the intensive ...

Страница 8: ...Cleaning protection is switched off Cleaning and maintenance Risk of burns The appliance becomes hot during operation Allow the appliance to cool down before cleaning Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Risk of electric shock ...

Страница 9: ... the metal mesh grease filters loosely in the dishwasher The metal mesh grease filters must not be wedged in Removing and installing the filter In order to guarantee efficient filtration of odours and grease the filter must be serviced regularly Metal grease filter The metal grease filter must be cleaned every 100 operating hours and at least after two months Activated charcoal filter only in circ...

Страница 10: ...ivated With the safety switch off function deacti vated the appli ance extends and retracts and will be ready to use again after around 30 seconds Risk of injury Risk of crushing when the appliance is extending and retracting Stop using the appli ance Keep children away from the appliance Note Disconnect the appliance from the power supply The appliance needs to be repaired Call the after sales se...

Страница 11: ...vice in the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer Yo...

Страница 12: ...951117a 9001070152 9001070152 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...

Отзывы: