INSTALLATION

For DB-3S Bases:

1.Remove the existing detector from the DB-3S base.
2.To install the DB-ADPT adapter into the DB-3S base,

align the notch in the outer flange of the adapter to the

raised surface on the outer ring of the base (Refer to

Figure 1).

3.Push the adapter into the base and rotate clockwise to

engage the electrical connections. The adapter will

automatically stop and lock into place.

4.To make the adapter to DB-3S interface tamperproof

in the base, use the Model DB-LK.

5.Install a Series 11 detector following the installation

instructions included with the detector.

NOTE:

If it becomes necessary to remove the

adapter, push the adapter up into the base

while rotating the adapter counterclockwise.

Continue to rotate counterclockwise until stop

is reached. Then pull downward to disengage

from the base. When the DB-LK lock is used,

disengage the locking mechanism prior to

removing the adapter.

Содержание DB-ADPT

Страница 1: ...ifferent model be aware that existing detector accessories connected to the base or air duct housing that were compatible with the old detector may not be compatible with the new detector Always read the Installation Instruc tions accompanying the detector to determine detec tor and accessory compatibility P N 315 094200 6 Installation Instructions Model DB ADPT Detector Base Adapter Fire Safety S...

Страница 2: ...apter will automatically stop and lock into place 4 To make the adapter to DB 3S interface tamperproof in the base use the Model DB LK 5 Install a Series 11 detector following the installation instructions included with the detector NOTE If it becomes necessary to remove the adapter push the adapter up into the base while rotating the adapter counterclockwise Continue to rotate counterclockwise un...

Страница 3: ... Update Kit 1 Remove the sensing compartment cover from the existing duct housing 2 Remove the existing detector from the duct housing 3 To install the adapter into the duct housing rotate the adapter counterclockwise on the outer ring of the base located in the duct housing until the adapter drops into place ...

Страница 4: ...ctions included with the detector and then install the new DA 304 sensing compartment cover Tighten the cover snugly but not so tightly as to warp cover and cause leakage around the edges NOTE If it becomes necessary to remove the adapter push the adapter down into the duct housing while rotating the adapter counterclockwise Continue to rotate counterclockwise until stop is reached Then pull upwar...

Отзывы: