Siemens DAC-NET Скачать руководство пользователя страница 7

A24205-A334-B839 (Edition 14)        

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

s

 

P/N 315-035100-14 

 

 

 

 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Figure 7  

DAC-NET Class X (ULC DCLC) D-NET Wiring 

 

   

Each connection between two nodes has to be installed in separate cable 

routes. 

All CAN cards and modules must be combined via CAN Bus. The CAN Bus 
requires a 120 Ohm termination resistor on both ends. Use a CAN terminator 
at CAN connectors and a termination resistor at screw terminals to fulfill it. 
They are shipped with DAC-NET. See Figures 9-14. 

All digital audio cards and modules must be connected via the ASI-Bus (LPB, 
AIC, ZAC-40, ZAM-180, XDMC). The ASI-Bus consists of 4 pairs (Part of CC-
5). They require four 120 Ohm termination resistors on both ends. Use an ASI 
terminator at 60-pin connectors to fulfill it. They are shipped with DAC-NET. 
See Figures 9-14. The PMI/PMI-2/PMI-3 provides ASI termination at one end 
when used. 

The Analog Audio Bus includes three audio signals with a level of 
0dBu/+6dBu (LVM microphone, LVM monitor speaker, FMT Phone). The LPB 
supervises the microphone signal wiring. The supervision requires an EOL 
resistor 3.3K. The EOL resistor is integrated in the LVM. 

   

If one LVM is mounted, the jumper P7 must be set in position 1 – 2. 

LVM default factory setting: Jumper P7 in position 1 – 2 

NOTES 
1. 

Power limited. 

2. 

Use twisted pair. 

3. 

Terminate shields at the entrance of 
the enclosure. 

4. 

18AWG (Ø 0,5m) Min.  
12 AWG (2,5mm²) Max. 

5. 

The two pairs between the nodes can 
be in one cable. 

6. 

Max. cable length between DAC-NETs: 
300m 
(38

 

 Ø 0,6mm) 

(21

 

 Ø 0,8mm) with cat 3 cable as 

J-Y(ST)Y. 

7. 

Max. cable length between DAC-NETs: 
900m 
(157

 

 Ø 0,51mm) with cat 5 cable 

as J-02YS(ST)Y. 

8. 

Max. cable length between DAC-NETs: 
700m 
(30

  

AWG 18

 

(19

  

AWG 16

  

(12

  

AWG 14

 with cable  

18B FPLR or 1pr. 16B FPLR or 1pr. 
14B FPLR. 

9. 

Distance between the first DAC-NET 
and last DAC-NET must not exceed 
wire lengths specified in Notes 6-8.  

10. 

10km max. total distance around the 
ring.  

11. 

32 DAC-NETs Max. 

12. 

Positive or negative ground fault 
detected at <5k 

 for terminals 1-8.  

 

 

 

 

Return 

Return  

 

Main

Main

Main

Return

Return out a (+)

Return in a (+)

Return in b (-)

Return out b (-)

Main in a (+)

Main out a (+)

Main out b (-)

Main in b (-)

Supervised
power limited

Supervised
power limited

can be in one cable

ONE SLOT OF CC-5 / CC-2

 

17

 

19

 

21

 

23

 

18

 

20

 

22

 

24

 

 

Do not use

 

 

 

FIRST DAC-NET

Do not use

1

 

3

 

5

 

7

 

2

 

4

 

6

 

8

 

 

11

 

13

 

15

 

 

12

 

14

 

16

 

9

10

RESISTOR 3.3K
P/N 140-03721 (US/CA)
C24235-A1-K14 (GE)

 

17

 

19

 

21

 

23

 

18

 

20

 

22

 

24

 

Do not use

 

 

 

Do not use

ONE SLOT OF CC-5 / CC-2

1

 

3

 

5

 

7

 

2

 

4

 

6

 

8

 

 

11

 

13

 

15

 

 

12

 

14

 

16

 

9

10

RESISTOR 3.3K
P/N 140-03721 (US/CA)
C24235-A1-K14 (GE)

 

17

19

21

23

18

20

22

24

 

 

Do not use

 

 

 

LAST DAC-NET

ONE SLOT OF CC-5 / CC-2

Do not use

1

 

3

 

5

 

7

 

2

 

4

 

6

 

8

 

 

11

 

13

 

15

 

 

12

 

14

 

16

 

9

10

RESISTOR 3.3K
P/N 140-03721 (US/CA)
C24235-A1-K14 (GE)

Содержание DAC-NET

Страница 1: ...s CAN module has a fixed CAN address 100 and provides two inputs One is for the microphone located at the LVM and the other connects the internal telephone system Additionally the LPB provides one output for the monitor speaker located at the LVM For more information refer to the LPB Installation Instructions P N 315 035200 A24205 A334 B836 Features The D NET is supervised for open short and groun...

Страница 2: ... Style 7 ULC DCLC Class B The node with the lowest node number master sends the data stream from Main Out to Main In at the next node The last node combines Main In with Return Out and returns the data stream back When the data stream comes back to the node with the lowest node number this node combines Return In with Main Out and sends it to Main In of the next node Figure 2 DAC NET D NET Class B...

Страница 3: ...en LEDs for the DAC NET and one D NET address switch and four LEDs for the D NET For the optionally mounted LPB there is one reset switch and eight LEDs as shown in Figure 1 A reset switch is located on the top of the front panel Pushing the reset switch re initializes the DAC NET operation The LEDs follow the reset switch Their functions are defined as follows DAC NET POWER Green Normally ON When...

Страница 4: ... open circuit or short circuit D NET TRBL _ MAIN IN Yellow Normally OFF When illuminated indicates RETURN OUT that the DAC NET has detected a trouble on Main In GND FAULT Yellow Normally OFF When illuminated indicates that the DAC NET has detected a ground fault on one of its field wires before the node TRBL _ MAIN OUT Yellow Normally OFF When illuminated indicates RETURN IN that the DAC NET has d...

Страница 5: ...e front panel Refer to Figure 1 for the location of the switch The address at the DAC NET front panel must be the same as the address selected in the Zeus Programming Tool To increment each digit of the address press the button above the desired digit to decrement each digit press the button below the desired digit The range of allowable network addresses is from 0 to 9 left digit and allowable no...

Страница 6: ... 17 19 21 23 18 20 22 24 17 19 21 23 18 20 22 24 Do not use Do not use Do not use FIRST DAC NET LAST DAC NET Do not use ONE SLOT OF CC 5 CC 2 Do not use ONE SLOT OF CC 5 CC 2 Do not use 1 3 5 7 2 4 6 8 11 13 15 12 14 16 1 3 5 7 2 4 6 8 11 13 15 12 14 16 1 3 5 7 2 4 6 8 11 13 15 12 14 16 9 10 RESISTOR 3 3K P N 140 03721 US CA C24235 A1 K14 GE 9 10 RESISTOR 3 3K P N 140 03721 US CA C24235 A1 K14 GE ...

Страница 7: ...limited 2 Use twisted pair 3 Terminate shields at the entrance of the enclosure 4 18AWG Ø 0 5m Min 12 AWG 2 5mm Max 5 The two pairs between the nodes can be in one cable 6 Max cable length between DAC NETs 300m 38 Ø 0 6mm 21 Ø 0 8mm with cat 3 cable as J Y ST Y 7 Max cable length between DAC NETs 900m 157 Ø 0 51mm with cat 5 cable as J 02YS ST Y 8 Max cable length between DAC NETs 700m 30 AWG 18 1...

Страница 8: ...MI PMI 2 PMI 3 has it already inside Install an ASI terminator into the 60 pin connector on the PSC 12 Analog Audio BUS Install the Analog Audio cable into the 10 pin connector of the PMI PMI 2 PMI 3 Install the other end of the Analog Audio cable into one 10 pin connector of the LVM If there is a FMT install a further Analog Audio cable into the second 10 pin connector of the LVM and the other en...

Страница 9: ... CAN TERMINATOR P N 110 134215 C24235 A1 K2 FMT TERMINATION RESISTOR C24235 A1 K18 PMI PMI 2 PMI 3 FMT shipped with the DAC NET shipped with the FMT ASI termination resistors are inside the PMI PMI 2 PMI 3 A separate ASI terminator is not required LVM P5 P4 P2 P3 CC 5 DAC NET C A N P4 L V M P3 P1 P7 P7 3 1 120 TERMINATION RESISTOR P N 140 034723 US CA C24235 A1 K12 DE S ASI TERMINATOR C24235 A1 K1...

Страница 10: ...6 7 8 9 0 S1 1 5 3 7 2 6 4 8 S2 1 5 3 7 2 6 4 8 OCM 16 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 TB2 TB1 P2 P3 TB3 TB4 SIM 16 1 _ 2 TB4 TB2 H N GND P12 _ P9 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 LCM 8 oder SCM 8 LCM 8 oder SCM 8 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 FCM 6 P1 P2 P...

Страница 11: ... Panel with RNI DETAIL A a a a b b b MIC MIC CAN CAN 6 5 4 3 2 1 TB2 RNI TB3 TB4 TB5 TB6 SPEAKER HNET or Class B Class X SPEAKER TB1 TB3 1 6 7 12 a a a b b b CAN MIC MIC CAN SPEAKER SPEAKER PSC 12 FMT FMT NOT SUPERVISED SUPERVISED CLASS B ULC DCLB SUPERVISED CLASS B 22 AWG MIN 12 AWG MAX 15 Ωs MAX PER PAIR USE TWISTED PAIR Figure 12 Remote Control Panel Detail A ...

Страница 12: ...A24205 A334 B839 Edition 14 s P N 315 035100 14 12 Figure 13 Multiple Remote Control Panels ...

Страница 13: ...PEAKER SPEAKER a a a a a a a a a b b b b b b b b b 6 5 4 3 2 1 TB1 TB3 1 6 7 12 CAN MIC MIC CAN SPEAKER SPEAKER PSC 12 a a a b b b DETAIL A HNET or Class B Class X HNET or Class B Class X FMT FMT FMT SUPERVISED CLASS B NOT SUPERVISED SUPERVISED CLASS B ULC DCLB 22 AWG MIN 12 AWG MAX 15 Ωs MAX PER PAIR USE TWISTED PAIR Figure 14 Multiple Remote Control Panels Detail A ...

Страница 14: ... Can Termination Resistor 120 Ohms C24235 A1 K12 P N 140 034723 1 External Alarm EOL Resistor 3 3K Ohms C24235 A1 K14 P N 140 034721 1 External Alarm Resistor 680 Ohms C24235 A1 K13 Not Available 1 Anti Interference Capacitor 6 8µF 100V bipolar C24235 A1 K19 Not Available ELECTRICAL RATINGS Power Consumption DAC NET 24V Back Plane Current 230 mA 24V Screw Terminal Current 0 6 2V Back Plane Current...

Страница 15: ...e Slide the card in until the card edge connectors contact the receptacles on the motherboard Verify that the DIN connectors of the card and the card cage aligned properly The card can only plug in one direction to the card cage if it does not align DO NOT FORCE the card Place thumbs on the front panel adjacent to the captive screws and gently apply even pressure on the card until the connectors s...

Страница 16: ...hensive state of the art security concept that is customized to individual security needs Such a security concept may result in additional site specific preventive action to ensure that the building comfort fire safety security management or physical security system for your site are operated in a secure manner These measures may include but are not limited to separating networks physically protec...

Отзывы: