Содержание CPU 1518HF-4 PN

Страница 1: ......

Страница 2: ...1518HF 4 PN 6ES7518 4JP00 0AB0 Equipment Manual 05 2021 A5E49868646 AA Preface S7 1500R H Documentation Guide 1 Product overview 2 Connecting 3 Alarm error and system messages 4 Technical specifications 5 Dimension drawing A ...

Страница 3: ...by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens product...

Страница 4: ...e fail safe system SIMATIC Safety SIMATIC Safety Configuring and Programming https support industry siemens com cs ww en view 54110126 programming and operating manual Conventions STEP 7 In this documentation STEP 7 is used as a synonym for all versions of the configuration and programming software STEP 7 TIA Portal Please also observe notes marked as follows Note A note contains important informa...

Страница 5: ...versions are used Use of product versions that are no longer supported and failure to apply the latest updates may increase customers exposure to cyber threats To stay informed about product updates subscribe to the Siemens Industrial Security RSS Feed visit https www siemens com industrialsecurity You can find current information on the following topics quickly and easily here Product support All...

Страница 6: ...4 2 4 Operator controls and display elements 17 2 4 1 Front view of the CPU with closed front flap 17 2 4 2 Front view of the CPU without front flaps 19 2 4 3 Rear view of the CPU 20 2 4 4 Bottom view 21 2 5 Mode selector 22 3 Connecting 23 3 1 Terminal assignment 23 4 Alarm error and system messages 28 4 1 Status and error display of the CPU 28 5 Technical specifications 33 5 1 Technical specific...

Страница 7: ...rogramming Device information Product manuals contain a compact description of the module specific information such as properties wiring diagrams characteristics and technical specifications General information The function manuals contain detailed descriptions on general topics regarding the redundant S7 1500R H system e g diagnostics communication You can download the documentation free of charg...

Страница 8: ...6630375 mySupport With mySupport your personal workspace you make the best out of your Industry Online Support In mySupport you can save filters favorites and tags request CAx data and compile your personal library in the Documentation area In addition your data is already filled out in support requests and you can get an overview of your current requests at any time You must register once to use ...

Страница 9: ...erating principle Structure The S7 1500H redundant system consists of the following components Two CPUs of the type CPU 1518HF 4 PN Two SIMATIC memory cards Four synchronization modules two synchronization modules in each H CPU Two redundancy connections two duplex fiber optic cables IO devices Load power supply optional ...

Страница 10: ...X1 P1 R and X1 P2 R of the CPUs Optional load current supply First CPU Mounting rail with integrated DIN rail profile Second CPU Location of the synchronization modules not visible in graphic Redundancy connections fiber optic cables PROFINET cable PROFINET ring Figure 2 1 Configuration example for S7 1500H Note Standard rail adapter You mount the CPUs on a standardized 35 mm rail using the standa...

Страница 11: ... CPUs in the event of a primary CPU failure If the primary CPU fails the backup CPU retains control of the process as the new primary CPU at the point of interruption The redundancy connections consist of two fiber optic cables which directly connect the CPUs via plug in synchronization modules The integrated F functionality with Safety Integrated processes standard and safety programs You can fin...

Страница 12: ... Manual 05 2021 A5E49868646 AA 11 2 2 Hardware properties Article number 6ES7518 4JP00 0AB0 View of the module The figure below shows CPU 1518HF 4 PN Figure 2 2 CPU 1518HF 4 PN Note Protective film Note that there is a removable protective film on the display when the CPUs are delivered ...

Страница 13: ...PROFINET device name and the redundancy ID of the CPU The system IP address can be viewed via STEP 7 but not in the display In addition to the functions listed here a large number of other functions are available on the display These additional functions are described in the SIMATIC S7 1500 Display Simulator Redundant System S7 1500R H https support industry siemens com cs ww en view 109754833 Sys...

Страница 14: ...face with one port X2 P1 and an X3 interface with one port X3 P1 Interfaces X2 and X3 support the basic functions of PROFINET H Sync interfaces X4 P1 and X5 P1 Die CPU has an X4 interface with one port X4 P1 and an X5 interface with one port X5 P1 The X4 and X5 interfaces are reserved for the synchro nization of the two CPUs Synchronization modules Make the redundancy connections between the two C...

Страница 15: ...or according to EN ISO 13849 1 Additional password protection for F configuration and F program is set up for IT security SIMATIC Safety Configuring and Programming https support industry siemens co m cs ww en view 54110126 pro gramming and operating manual Integrated system diag nostics The system automatically generates the messages for the system diagnostics and outputs these messages via a pro...

Страница 16: ...re that an alternative commu nication path is made available if a transmission link fails Within the PROFINET ring the H CPUs assume the role of the MRP Manager following appropriate project con figuration and all other devices in the ring assume the role of the MRP clients MRP interconnection The process MRP interconnection is an enhancement of MRP and allows redundant coupling of two or more rin...

Страница 17: ...n by default Integrity protection identifies possible manipulations of engineering data on the SIMATIC memory card or dur ing data transfer between STEP 7 and the CPUs Integrity protection also checks the communication from a SIMATIC HMI system to the CPUs for possible manipulations of engineering data If integrity protection identifies the manipulation of engineering data the user receives a corr...

Страница 18: ... with display Display Control keys Front panel of the X4 and X5 interfaces Figure 2 3 View of CPU 1518HF 4 PN with front panel front Note Temperature range for display To increase its service life the display switches off at a temperature below the permitted operating temperature of the device When the display cools down it automatically switches itself on again When the display is switched off th...

Страница 19: ...he front panel to protect the SIMATIC memory card and the mode selector of the CPU against unauthorized access You can attach a security seal or a padlock with a hoop diameter of 3 mm to the front panel Figure 2 4 Locking latch on the CPU In addition to the mechanical lock you can also block access to a password protected CPU on the display local lock and assign a password for the display You can ...

Страница 20: ...nd X5 interfaces MAC addresses of the X4 and X5 interfaces H Sync X4 and X5 interfaces with 1 port each not visible in graphic Fixing screws Connector for power supply PROFINET IO interface X1 with 2 ports PROFINET IO interface X2 and X3 each with 1 port MAC addresses of the X1 X2 and X3 interfaces LED displays for the ports of the X1 X2 and X3 interfaces Slot for the SIMATIC memory card Display c...

Страница 21: ...PU 1518HF 4 PN 6ES7518 4JP00 0AB0 20 Equipment Manual 05 2021 A5E49868646 AA 2 4 3 Rear view of the CPU The following figure shows the connection elements on the rear of CPU 1518HF 4 PN Shield contact surfaces Fixing screws Figure 2 6 View of CPU 1518HF 4 PN rear ...

Страница 22: ...nchronization modules The figure below shows the position of the interfaces on the underside of the CPU PROFINET IO interface X2 with 1 port PROFINET IO interface X3 with 1 port PROFINET IO interface X1 with 2 ports H Sync interface X4 H Sync channel 1 without synchronization module H Sync interface X5 H Sync channel 2 without synchronization module Figure 2 7 Bottom view ...

Страница 23: ...shows the position of the switch and the corresponding meaning Table 2 1 Mode switch settings Position Meaning Explanation RUN RUN operating state The CPU has permission to go to RUN STOP STOP operating state The CPU does not have permission to go to RUN MRES Memory reset Position for CPU memory reset Reference You can find a brief overview of the various operating states and system states in the ...

Страница 24: ...gnal names and the descriptions of the pin assignment of the 24 V DC supply voltage Table 3 1 Pin assignment 24 V DC supply voltage View Signal name 1 Description Connector 1 1L 24 V DC of the supply voltage 2 1M Ground of the supply voltage 3 2M Ground of the supply voltage for loop through 2 4 2L 24 V DC of the supply voltage for loop through 2 1 1L and 2L as well as 1M and 2M are bridged intern...

Страница 25: ...a switch MDI X When autonegotiation is activated autocrossing is in effect and the RJ45 socket is allocated either as data terminal equipment MDI or a switch MDI X Figure 3 1 Interface assignment X1 PROFINET interface X2 with 1 port X2 P1 and X3 with port X3 P1 The assignment corresponds to the Ethernet standard for a RJ45 connector Autocrossing is always active on X2 and X3 This means the RJ45 so...

Страница 26: ... on the topic Accessories spare parts in the system manual for Redundant System S7 1500R H https support industry siemens com cs ww en view 109754833 Assignment of the MAC addresses CPU 1518HF 4 PN has for each CPU One PROFINET interface with two ports Two PROFINET interfaces with one port each Two H Sync interfaces with one port each Each of the interfaces has a MAC address Each port also has a s...

Страница 27: ...s 2 Port X1 P1 R required for LLDP for example MAC address 3 Port X1 P2 R required for LLDP for example MAC address 4 PROFINET interface X2 visible in STEP 7 when devices are accessible Front printed MAC address 5 Port X2 P1 required for LLDP for example MAC address 6 PROFINET interface X3 visible in STEP 7 when devices are accessible Front printed MAC address 7 Port X3 P1 required for LLDP for ex...

Страница 28: ...1 H Sync interface X4 port 1 Electronics HSYNC X5 P1 H Sync interface X5 port 1 PROFINET 2 port switch L 24 V DC supply voltage Synchronization interface M Ground Backplane bus connection connection to backplane bus not configurable R S RUN STOP LED yellow green Internal supply voltage ER ERROR LED red Supply of the 24 V DC supply voltage X80 MT MAINT LED yellow PN X1 P1 R PROFINET interface X1 po...

Страница 29: ... view 109754833 You can find additional information on the topic of Operating states and system states as well as various failure scenarios in the system manual for S7 1500R H Redundant System https support industry siemens com cs ww en view 109754833 LED display The figure below shows the LED displays of the CPU 1518HF 4 PN RUN STOP LED yellow green LED ERROR LED red LED MAINT LED yellow LED LINK...

Страница 30: ...the current operating state and diagnostics status RUN STOP LED ERROR LED MAINT LED The LEDs indicate the operating state of the respective CPU within the redundant system Operating states describe the behavior of a single CPU at a specific time The combination of the operating states of the CPUs forms the system state The following figure shows the possible operating states of the CPUs and the re...

Страница 31: ...rating state and diagnostics status Note LED patterns of the S7 1500H redundant system Note that it is not always possible to Determine the state of the CPU from the signal pattern of individual LEDs Determine the state of the other CPU from the signal pattern of a CPU The Meaning column only shows a possible typical cause To investigate the cause of the signal pattern use the diagnostic buffer an...

Страница 32: ... in STARTUP operating state The backup CPU is in SYNCUP operating state The backup CPU has not yet been restarted for SYNCUP during this phase LED flashes yellow LED off LED off The CPU performs a warm restart LED lit green LED off LED lit yellow Maintenance demanded for the plant You need to check replace the affected hardware within a short period of time The primary CPU is in the RUN or RUN Syn...

Страница 33: ...ble 4 2 Meaning of LINK RX TX LED LINK TX RX LED Meaning Off There is no connection between the interface of the device and a communication partner No data is currently being sent received via the interface There is no LINK connection The redundancy connections were interrupted Flashes green The CPU performs an LED flash test Illuminated green There is a connection between the interface of the dev...

Страница 34: ...duct function I M data Yes I M0 to I M3 Isochronous mode No Display Screen diagonal cm 6 1 cm Control elements Number of keys 6 Mode selector switch 1 Supply voltage Type of supply voltage 24 V DC permissible range lower limit DC 19 2 V permissible range upper limit DC 28 8 V Reverse polarity protection Yes Mains buffering Mains voltage failure stored energy time 5 ms Input current Current consump...

Страница 35: ...B FB FC DB and UDTs DB Number range 1 60 999 subdivided into number range that can be used by the user 1 59 999 and number range of DBs created via SFC 86 60 000 60 999 Size max 16 Mbyte For DBs with absolute addressing the max size is 64 KB FB Number range 0 65 535 Size max 1 Mbyte FC Number range 0 65 535 Size max 1 Mbyte OB Size max 1 Mbyte Number of free cycle OBs 100 Number of time alarm OBs ...

Страница 36: ... data area incl timers counters flags max 768 kbyte In total available retentive memory for bit memories timers counters DBs and technol ogy data axes 700 KB Flag Size max 16 kbyte Number of clock memories 8 8 clock memory bit grouped into one clock memory byte Data blocks Retentivity adjustable Yes Retentivity preset No Local data per priority class max 64 kbyte max 16 KB per block Address area N...

Страница 37: ...ber 16 Clock synchronization supported Yes on Ethernet via NTP Yes Interfaces Number of PROFINET interfaces 3 1 Interface Interface types RJ 45 Ethernet Yes X1 Number of ports 2 integrated switch Yes Protocols IP protocol Yes IPv4 PROFINET IO Controller Yes PROFINET IO Device No SIMATIC communication Yes Only Server Open IE communication Yes Optionally also encrypted Web server No Media redundancy...

Страница 38: ...ation Yes Optionally also encrypted Web server No Media redundancy No 3 Interface Interface types RJ 45 Ethernet Yes X3 Number of ports 1 integrated switch No Protocols IP protocol Yes IPv4 SIMATIC communication Yes Only Server Open IE communication Yes 4 Interface Interface type Pluggable synchronization submodule FO Plug in interface modules Synchronization module 6ES7960 1CB00 0AA5 or 6ES7960 1...

Страница 39: ...2 Edition 2 0 MRP interconnection supported Yes as MRP ring node according to IEC 62439 2 Edition 3 0 MRPD No Switchover time on line break typ 200 ms PROFINET MRP Number of stations in the ring max 50 SIMATIC communication PG OP communication Yes encryption with TLS V1 3 pre selected S7 routing Yes S7 communication as server Yes S7 communication as client No Open IE communication TCP IP Yes Data ...

Страница 40: ...gram_Alarm block ProDiag or GRAPH Number of loadable program messages in RUN max 5 000 Number of simultaneously active program alarms Number of program alarms 4 000 Number of alarms for system diagnostics 1 000 Test commissioning functions Joint commission Team Engineering No Status block Yes Up to 16 simultaneously Single step No Number of breakpoints 20 Breakpoints are only supported in RUN Solo...

Страница 41: ...temperature Counting and measuring Yes High speed counter No Standards approvals certificates Suitable for safety functions Yes e g emergency stop acknowledgment but ton Highest safety class achievable in safety mode Performance level according to ISO 13849 1 PLe SIL acc to IEC 61508 SIL 3 Probability of failure for service life of 20 years and repair time of 100 hours Low demand mode PFDavg in ac...

Страница 42: ...c tion Yes Copy protection Yes Block protection Yes Access protection protection of confidential configuration data Yes Password for display Yes Protection level Write protection Yes Protection level Read write protection Yes Protection level Write protection for Fail safe Yes Protection level Complete protection Yes Cycle time monitoring lower limit adjustable minimum cycle time upper limit adjus...

Страница 43: ...g This section contains the dimension drawing of the module on the mounting rail as well as a dimension drawing with the front panel open Keep to the dimensions when installing in cabinets control rooms etc Dimension drawings of the CPU 1518HF 4 PN Figure A 1 Dimension drawing of the CPU 1518HF 4 PN front and side view ...

Страница 44: ...Dimension drawing A 1 Dimension drawing CPU 1518HF 4 PN 6ES7518 4JP00 0AB0 Equipment Manual 05 2021 A5E49868646 AA 43 Figure A 2 Dimension drawing of the CPU 1518HF 4 PN side view with front panel open ...