background image

Index 
  

 

CP 5623/CP 5624 

28

 

Operating Instructions, 09/2013, C79000-G8976-C281-03 

 

Содержание CP 5623

Страница 1: ..._ ___________________ ___________________ ___________________ SIMATIC NET PG PC PROFIBUS CP 5623 CP 5624 Operating Instructions 09 2013 C79000 G8976 C281 03 Preface Description of the device 1 Software installation 2 Hardware installation 3 Configuration 4 Technical specifications 5 Approvals A ...

Страница 2: ...operated only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING S...

Страница 3: ...24 order number 6GK1 562 4AA00 Content of this documentation These operating instructions contain information about the installation and configuration of the CP 5623 and CP 5624 communications processors Updated operating instructions on the Internet You will find the current version of these operating instructions on the Product Support pages under the following entry ID 38549256 http support aut...

Страница 4: ... on installing the SIMATIC NET PC software Entry ID 42784913 http support automation siemens com WW view en 42784913 System manual PROFIBUS Network Manual In this document you will find detailed information about setting up a PROFIBUS network Entry ID 35222591 http support automation siemens com WW view en 35222591 SIMATIC NET documentation You will find the entire SIMATIC NET documentation on the...

Страница 5: ...fferent courses SITRAIN covers the entire Siemens product and system spectrum in the field of automation and drive technology Apart from the classic range of courses we also offer training tailored for individual needs and a combination of different teaching media and sequences for example self learning programs on CD ROM or on the Internet You will find detailed information on the training curric...

Страница 6: ...Preface CP 5623 CP 5624 6 Operating Instructions 09 2013 C79000 G8976 C281 03 ...

Страница 7: ...1 3 PROFIBUS interface 11 1 4 Meaning of the LED display 13 2 Software installation 15 2 1 Installing the SIMATIC NET PC software 15 2 2 Uninstalling the SIMATIC NET PC software 15 2 3 Alternative software packets 16 3 Hardware installation 17 3 1 Safety notices 17 3 2 Installing hardware 18 3 3 Hardware compatibility 18 4 Configuration 21 5 Technical specifications 23 A Approvals 25 Index 27 ...

Страница 8: ...Table of contents CP 5623 CP 5624 8 Operating Instructions 09 2013 C79000 G8976 C281 03 ...

Страница 9: ...n be connected The additional interface signals for a direct link to a PLC Programmable Logic Controller are supported up to 187 5 Kbps Installation in PGs and PCs with a PCI Express slot The following is supported PCI Express x1 Can also be operated in x4 x8 and x16 slots Plug and play Optimized for fast DP master operation DP Base with up to 124 DP slaves with full data consistency Relief of the...

Страница 10: ...P 5624 Properties The CP 5624 is a communications processor for connecting PCs personal computers or PGs programming devices to PROFIBUS and MPI networks In addition to the properties of the CP 5623 the CP 5624 also has the following features Additional PROFIBUS connection as DP slave to a second DP network DP master and DP slave can be operated at the same time Program controlled data transfer be...

Страница 11: ...LEDs 2 PROFIBUS interface PB1 master only 3 PROFIBUS interface PB2 slave only 1 3 PROFIBUS interface Note Connector with 180 cable outlet Use the bus connector with a 180 cable outlet if you want to use the lower PROFIBUS connector PB2 slave only or both PROFIBUS connectors at the same time You can obtain these connectors for example under the following order numbers 6GK1 500 0FC10 6GK1 500 0EA02 ...

Страница 12: ...2 is not connected With other MPI DP components the return line of the floating 24 V power supply may be via this pin 3 LTG_B Signal line B of the PROFIBUS connector Input output 4 RTSAS RTSAS input signal for direct MPI link The control signal is 1 active when the automation system connected over a special MPI cable is sending Input 5 M5EXT M5EXT return line GND of the 5 V power supply The curren...

Страница 13: ...tion Green flashes at one second intervals Bad database Green flashes fast yellow is off Module not started normal status following reset Green and yellow flashing alternately When using more than one module in a PG PC Identification of the module by a diagnostics tool Green and yellow flashing synchronized Exception status error in firmware One of the two LEDs is on the second flashes quickly Err...

Страница 14: ...Description of the device 1 4 Meaning of the LED display CP 5623 CP 5624 14 Operating Instructions 09 2013 C79000 G8976 C281 03 ...

Страница 15: ... your PG PC Prior to hardware installation Install the software as described in the installation manual SIMATIC NET PC Software You will find this installation manual on the Product Support pages under the entry ID 61630923 http support automation siemens com WW view en 61630923 You should also note the current information on the SIMATIC NET PC software on the Product Support pages Support http su...

Страница 16: ...anual SIMATIC NET PC Software You will find the installation manual on the SIMATIC NET DVD or on the Product Support pages under the following entry ID 61630923 http support automation siemens com WW view en 61630923 2 3 Alternative software packets Alternatives to SIMATIC NET PC software To operate the CP alternative software packages such as STEP 7 V5 5 or STEP 7 Professional TIA Portal are avai...

Страница 17: ...sensitive devices ESD Pick up components and modules only by their edges Do not touch the pins or conductors Before opening the PG PC make sure that you discharge any electrostatic charge from your body You can do this by touching metal parts on the back panel of the PG PC pulling the power plug Make sure that you also discharge any electrostatic charge from tools you intend to use for the work on...

Страница 18: ...nnector 2 Open the computer housing as described in the manual accompanying your PG PC 3 Remove the cover from a free PCI Express slot 4 Remove the CP from its packaging 5 Insert the CP in the PCI Express slot and secure it Make sure that the CP is correctly inserted and secured 6 Close the computer housing as described in the manual accompanying your PG PC 7 Insert the power plug into the socket ...

Страница 19: ...5614 series are PCI cards The CP 5623 and CP 5624 communications processors are PCI Express cards This means that you can only replace previous versions with a CP 5623 CP 5624 if there is a free PCI Express slot available in the PG PC Note No configuration changes necessary You can adopt the configuration of the previous CP To do this you simply need to reload the configuration Procedure for repla...

Страница 20: ...Hardware installation 3 3 Hardware compatibility CP 5623 CP 5624 20 Operating Instructions 09 2013 C79000 G8976 C281 03 ...

Страница 21: ... CP 5624 available in the hardware catalog of your STEP 7 version or NCM PC version you can also select a previous version for configuration For the CP 5623 select a configuration of CP 5613 A3 CP 5613 A2 or CP 5613 For the CP 5624 select a configuration of CP 5614 A3 CP 5614 A2 or CP 5614 The CP 5623 CP 5624 is downwards compatible with the configurations of the previous versions NOTICE The DP sl...

Страница 22: ...Configuration CP 5623 CP 5624 22 Operating Instructions 09 2013 C79000 G8976 C281 03 ...

Страница 23: ...ace signals Connection to PG PC PCI Express x1 V 1 0a plug and play Can also be operated in x4 x8 or x16 Electrical specifications of the PCI plug in connector Operating voltage Rated voltage 3 3 VDC and 12 VDC Permitted range DC 3 0 to 3 6 V for 3 3 VDC 11 0 13 0 VDC for 12 VDC Properties Safety extra low voltage SELV to EN 60950 Current consumption Typical CP 5623 CP 5624 720 mA at 3 3 V and 250...

Страница 24: ... Shock EN 60068 2 29 Half sine 250 m s2 25 g 6 ms Design dimensions and weight Module format Flat module Short PCI card Weight For CP 5623 For CP 5624 102 g 117 g Dimensions W x H x D For CP 5623 For CP 5624 21 6 x 126 3 x 180 5 21 6 x 126 3 x 180 5 Electromagnetic compatibility Emission to EN 55022 to FCC Class B Class B Immunity On signal cables Surge to EN 610004 5 Burst to EN 61000 4 3 2 kV 2 ...

Страница 25: ...000 6 4 EN 61000 6 2 EC declaration of conformity You will find the EC declaration of conformity for this communications processor on the Product Support pages under the following entry ID 63367995 http support automation siemens com WW view en 63367995 Machinery directive This communications processor is not a machine in the sense of the EC directive 2006 42 EEC Machinery Directive There is there...

Страница 26: ...oes cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to wh...

Страница 27: ... 18 CP 5614 19 D Documentation on the Internet 3 D sub female connector 12 E Electric shock 17 Electrostatic charge 17 ESD directives 17 G Glossary 5 L LEDs 13 M Mounting 17 N NCM PC 21 Number of CPs permitted 18 O Oblique installation position 17 P PIN assignment 12 PROFIBUS network 12 R Replacing 19 S SIMATIC NET documentation 4 SIMATIC NET glossary 5 STEP 7 16 21 Support 4 T Training 5 ...

Страница 28: ...Index CP 5623 CP 5624 28 Operating Instructions 09 2013 C79000 G8976 C281 03 ...

Отзывы: