Siemens CCBS1337 Скачать руководство пользователя страница 2

English 

Package contents                           

• 

CCD camera 

• 

C/CS-mount adapter   

• 

CD containing remote control software and 
detailed operation manual 

• 

Quickstart manual 

Important                                         

 

This quick start guide is only intended for use by 
installers who have an adequate working knowledge 
of video systems! 
This guide outlines the most important information 
about the camera. It is, however, vital that you also 
refer to the full operating instructions on CD. 

Camera parts                                     

 

See figure 

B

,

 C

,

 D

 and 

E

 

1.  Back focus adjust ring 
2.  Back focus lock screw 
3.  Tripod mount hole 
4.  IRIS connector 
5.  Power indicator 
6.  BNC connector for composite video output 
7.  Power cord(or terminal) 
8.  Terminals for external control 
9.  Mini-DIN connector for Video output (Y/C) 
10. Lens selection switch 
11. OSD keypad 
12. PC connection port (factory test purpose only) 

Installing the camera                       

 

Step 1: Mounting the camera 

1.  Attach the camera to a wall bracket, ceiling 

bracket, pan/tilt mount or other suitable fitting. 
Use of the ¼ inch thread tripod mount hole (

3

) to 

prevent from rotation. 

2.  Mount the cable guide to the camera to ensure 

that the cables are retained securely in place (see 
figure 

A

). 

Step 2: Screw the lens onto the camera 

Select one of the following options: 

 

For C-mount lens: 

Add a CS-C adapter before 

camera, then screw the lens directly onto the 
camera   

 

For CS-mount lens: 

Screw the lens directly onto 

the camera (no adapter ring required).. 

Step 3: Connecting the lens

 

Two type of lens (DC or Video controlled) can be 
used for this camera. However, please take note to 
select DC or VIDEO lens using switch

 

(

10

)

 before 

connecting the Lens and make sure the wire 
connection for each type lens should conform to the 
pin assignment below. 

 
Then

 

connect the control cable to the IRIS connector 

(

4, 

side or rear) on the camera. 

Step 4: Connecting video signal 

Select one of the following options: 

 

For composite video: 

connect BNC connector 

VIDEO OUT (

6

) to the monitor with a coax cable. 

 

For Y/C connection: 

connect Mini-DIN 

connector Y/C (

9

) to the monitor. 

Step 5: Synchronization 

LL and INT mode are available for this camera. The 
factory default is Line lock mode when supplied by an 
AC power source. User can change the setting to INT 
as necessary. 

Step 6: Connecting control input 

Connect the control input on the terminals GND and 
AL IN (

8

).   

 

Step 7: Connecting RS485 data interface 

For connection with configuration software connect 
the interface cable to the RS485 terminals (

8

). 

Step 8: Connecting power supply   

Connect the power supply cable to the power 
connectors (

7

) (see figure 

E

): 

Caution 

If using a DC supply, make sure the polarity is 
correct. Incorrect connection may cause 
malfunction and/or damage to the camera.   

Select one of the following options 

 

For 12 V DC: 

 

Connect shielding to terminal GND (

13

). 

 

Connect 12 V (-) to terminal =DC12V- (

14

). 

 

Connect 12 V (+) to terminal =DC12V+ (

15

).

 

 

For 24 V AC: 

 

Connect 24 V (~) cables to terminals ~AC24V 
(

14 

and 

15

). 

 

Connect shielding to terminal GND (

13

). 

Adjusting camera settings           

Setting flange focal distance 

Caution: 

Risk of damage to camera! Ensure that the locking 
screw is loosened before turning the adjustment 
screw. Avoid forcing the adjustment screw. 

Fixed focus lenses 

1.  Loosen the locking screw (

2

) by turning it 

counter-clockwise. 

2.  Open the diaphragm to its fullest extent (either 

manually or via the on-screen menu). If the 
images are overexposed, or for lenses with 
automatic diaphragm adjustment: reduce lighting 
levels or hold a neutral grey filter in front of the 
lens. 

3.  Set the focus to 

4.  Point the camera at an object (at a distance of at 

least 2000 times the focal length of the lens). 

5.  Adjust the backfocus ring (

1

), alter the flange 

focal distance until the image is clearly in focus. 

6.  Re-tighten the locking screw (

2

). 

Varifocal lenses 

1.  Loosen the locking screw (

2

) by turning it 

counter-clockwise. 

2.  Open the diaphragm to its fullest extent (either 

manually or via the on-screen menu). If the 
images are overexposed, or for lenses with 
automatic diaphragm adjustment: reduce lighting 
levels or hold a neutral grey filter in front of the 
lens. 

3.  Set the focus to 

4.  Select the wide angle (min. focal length) setting. 
5.  Point the camera at an object (at a distance of at 

least 2000 times the focal length of the lens). 

6.  Adjust the backfocus ring (

1

), alter the flange 

focal distance until the image is clearly in focus. 

7.  Select the telescopic (max. focal length) setting 

and adjust the focus to improve image clarity. 

8.  Reset the camera to the minimum focal length 

(wide angle) and fine adjust the flange focal 
distance using the adjustment ring (

1

). 

9.  Re-tighten the locking screw (

2

). 

Setting camera parameters           

Camera parameters can be modified using the 
on-screen menu. The on-screen menu control keys 
are located on the left-hand side of the camera 
behind the sliding cover. The on-screen menu is 
displayed in English on the monitor.   

Control keys and their functions 

 

Use the 

ENTER 

key to access the on-screen 

menu. 

 

In the menu, use

 UP, DOWN, RIGHT, LEFT

 

button to navigate the OSD screen for all the 
functions 

 

To leave and save, move cursor to EXIT, then 
push 

ENTER

 button. 

 

To leave without save, move cursor to CANCEL, 

then push 

ENTER

 button 

 

Select DEFAULT to return to the factory setting 

The on-screen menu 

This summary only describes the main on-screen 
menu levels. For a description of the sub-menus, 
please refer to the full operating instructions in CD 

Day/ night mode 
D/ N mode switchover level 
D/ N mode delay time 
Exposure mode 
Shutter speed 
Maximum Gain 
External synchronism 
Backlight mode 

 
White balance 
Gamma value 
Picture sharpness 
Mirror function 
Privacy zone block 
Optional menu 
Remote control 
Exit the on-screen menu 

Operation and storage                   

Do not operate or store the unit in following locations: 

• 

Extremely hot or cold places. 

• 

Close to sources of strong magnetism. 

• 

Close to sources of powerful electromagnetic 
radiation such as radios or TV transmitters. 

• 

In humid or excessively dusty places. 

• 

Where exposed to mechanical vibrations. 

• 

Close to fluorescent lamps or objects reflecting 
light. 

• 

Under unstable or flickering light sources. 

Care and maintenance                   

The camera is maintenance-free. 
Small amounts of dirt or dust can be cleaned from the 
camera body using a clean soft cloth. If the unit tends 
to get very dirty, the camera should be placed within a 
protective housing. 

Specifications                                   

Active pixels: 

752(H) x 582(V) 

Scanning system: 

2:1 interlace PAL 

Hor. Resolution: 

520 TVL 

Min. Illumination: 

0.4Lux @F1.4 

S/N-Ratio: 

>50dB 

Synchronisation: 

Internal or Line-Lock 

Video Output: 

composite or Y/C 

Power requirement: 

DC12V/AC24V

±

10% or 

~AC100-240V±10% 50Hz 

Power consumption: 

8 VA (Max.) 

Camera weight: 

550g (Max.)   

Operating temperature :   -10 ~ +50 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Video Lens  DC Lens 

1. +12V 

1. Damp- 

2. NC 

2. Damp+ 

3. VIDEO 

3. Drive + 

4. GND 

4. Drive- 

D/N MODE 

D/N LEVEL 

D/N DELAY 

EXPOSURE 

SHUTTER 

GAIN 

SYNC 

BLC 

 

WHITE BAL 

GAMMA 

APERTURE 

MIRROR 

PRIVACY ZONE 

OPTION 

REMOTE 

EXIT 

D

at

a

 a

n

d

es

ig

su

bj

ec

to

 c

h

a

ng

w

ith

ou

no

tic

  

  

  

  

  

  

  

  

  

  

  

 ©

 2

00

S

ie

m

e

ns

 B

ui

ld

in

Te

ch

no

lo

gi

es

: F

ire

 a

nd

 S

ec

ur

ity

 P

ro

du

ct

Содержание CCBS1337

Страница 1: ...and should conform to all local codes Please connect the equipment to 12VDC or 24VAC UL Listed Class 2 power supply if this type of camera to be installed Waarschuwing Open de behuizing niet want dan loopt u het risico op een elektrische schok Laat alle reparaties door gekwalificeerde technici uitvoeren Stel dit product niet bloot aan regen of vocht want dat zou brand of een elektrische schok kunn...

Страница 2: ...stment reduce lighting levels or hold a neutral grey filter in front of the lens 3 Set the focus to 4 Point the camera at an object at a distance of at least 2000 times the focal length of the lens 5 Adjust the backfocus ring 1 alter the flange focal distance until the image is clearly in focus 6 Re tighten the locking screw 2 Varifocal lenses 1 Loosen the locking screw 2 by turning it counter clo...

Страница 3: ... brandpuntsinstelling verlaag de hoeveelheid omgevingslicht of houd een neutraal grijsfilter voor de lens 3 Stel de scherpte in op 4 Richt de camera op een object op een afstand van minimaal 2000 keer de brandpuntsafstand van de lens 5 Stel de brandpuntsafstand met de back focus ring 1 in op een beeld met optimale scherpte 6 Draai de borgschroef 2 weer vast Varifocuslens 1 Draai de borgschroef 2 l...

Страница 4: ...ringern Sie die Beleuchtungsstärke oder halten Sie einen neutralen Graufilter vor das Objektiv 3 Stellen Sie die Entfernung auf ein 4 Richten Sie die Kamera auf ein Objekt Entfernung min 2000 fache Objektivbrennweite 5 Stellen Sie den Back Focus Ring 1 ein und ändern Sie das Auflagemaß bis das Bild optimale Schärfe hat 6 Ziehen Sie die Lock Schraube wieder 2 fest Objektive mit variabler Brennweite...

Отзывы: