Siemens CCBS1337-LP Скачать руководство пользователя страница 2

Data and design subject to change without notice. / Supply subject to availability. 
© 2005 Copyright by 
Siemens Building Technologies AG 

 

We reserve all rights in this document and in the subject thereof. By acceptance of the document, the recipient acknowledges these rights 
and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our 
prior express written authorization, nor to use it for any purpose other than for which it was delivered to him. 

Dear Customer 

By selecting this SIEMENS product, you have chosen a professional device that 
guarantees the highest possible quality and reliability. We would like to thank you 
very much for your confidence in our products and kindly ask you to read the 
following instructions carefully before installing and using the product, in order to 
take full advantage of all quality features included in this product line. 

WARNING 

To reduce the risk of fire or electrical shock, do not expose this product to rain or 
moisture. It should be installed by a qualified service person and should conform to 
all local codes. Please connect the equipment to a 12 V DC or 24 V AC Class 2 
power supply if the LP camera model is to be installed. 

 

Содержание CCBS1337-LP

Страница 1: ...Fire Safety Security Products Siemens Building Technologies 1 3 inch Super High Res Day Night Camera CCBS1337 LP CCBS1337 MP Instruction Manual ...

Страница 2: ...im Dear Customer By selecting this SIEMENS product you have chosen a professional device that guarantees the highest possible quality and reliability We would like to thank you very much for your confidence in our products and kindly ask you to read the following instructions carefully before installing and using the product in order to take full advantage of all quality features included in this ...

Страница 3: ...6 2 Connector Pin Definitions 11 6 3 OSD Setting Hierarchy 12 7 Installing the Camera 13 7 1 Installation 13 7 2 Function Settings 13 7 2 1 D N MODE 14 7 2 2 D N LEVEL 15 7 2 3 D N DELAY 15 7 2 4 EXPOSURE 16 7 2 5 SHUTTER 16 7 2 6 GAIN 17 7 2 7 SYNC 17 7 2 8 BLC 18 7 2 9 WHITE BAL 18 7 2 10 GAMMA 19 7 2 11 APERTURE 19 7 2 12 MIRROR 20 7 2 13 PRIVACY ZONE 20 7 2 14 OPTION 21 7 2 14 1 BLEMISH DET 21...

Страница 4: ...4 Siemens Building Technologies Fire Safety Security Products 03 2005 7 2 16 NEXT BACK 24 7 2 17 EXIT 24 7 2 18 CANCEL 24 7 2 19 DEFAULT 24 8 Index 25 ...

Страница 5: ...signed to provide reasonable protection against harmful interference in a residential installation This equipment may generate uses and can radiate radio frequency energy and if not installed and used according to instructions may cause harmful interference with radio communications Be aware that any modifications not explicitly approved in this manual may void your equipment warranty The shielded...

Страница 6: ...4 1998 The EU certificate of conformity is available for official inspection and is held at Siemens Building Technologies SBT FSP DE Siemensallee 84 76187 Karlsruhe Germany 2 Ordering Data Designation Order No Approx Weight kg CCBS1337 LP 1 3 inch Super High Res Day Night Camera 520 TVL PAL 12 V DC 24 V AC 50 Hz 2GF1118 8FA 0 45 CCBS1337 MP 1 3 inch Super High Res Day Night Camera 520 TVL PAL 100 ...

Страница 7: ...authorized to do so Opening the camera may expose you to dangerous voltages or other hazards Refer all servicing to qualified personnel only 4 2 Cleaning Do not touch the imaging surface of the sensor Use a soft cloth moistened with alcohol to clean the surface if it is touched accidentally 4 3 Transportation Use the original packing material or materials of equal quality 4 4 CCD Characteristics T...

Страница 8: ...0IRE video output Minimum illumination BW 0 08 lux F 1 4 AGC 30dB 50IRE video output S N ratio 50 dB 12 V DC 10 regulated power supply 24 V AC 10 50 Hz Power source 100 240 V AC 10 50 Hz Power consumption 8 VA max as DN filter moving Ambient conditions 10 50 C max relative humidity 95 no condensation Dimensions in mm 122 L x 72 W x 63 H Shutter control Auto 1 50 to 1 100K sec Manual 1 50 1 120 1 2...

Страница 9: ...GH MID LOW White balance ATW1 2600 K 6000 K ATW2 2500 K 10 000 K Manual 32 steps by push button for R and B Iris control Video DC iris for galvanometer lens Camera text 16 characters OSD control 5 control keys on the side panel of camera Default settings Default setting restored by pushing the DEFAULT button Remote control RS 485 Alarm IN 1CH Alarm OUT NC or NO selectable ...

Страница 10: ...echnologies Fire Safety Security Products 03 2005 6 Camera Parts Connections 6 1 Camera Parts 1 Back focus adjustment ring 2 Back focus lock screw 3 Tripod mount hole 4 IRIS connector 5 Power indicator 6 Video output 7 Power cord or power terminal ...

Страница 11: ...ircuit 7 B W 8 C L 9 GND If D N MODE set in manual mode this function will be enabled If B W GND are shorted the video signal is monochrome If C L GND are shorted the video signal is color 9 Y C terminal 10 Video DC lens selection 11 OSD control button 12 PC connection port For factory testing only the user is not recommended to use this function 6 2 Connector Pin Definitions IRIS pin assignment V...

Страница 12: ... 120 1 250 GAIN NORMAL TURBO SYNC INT LL BLC OFF EXPOSURE ALC LENS TYPE ELC LENS LEVEL MANUAL 10 15 20 MID OFF 1 500 1 1K 1 2K 1 4K 1 10K 1 100K BLC1 BLC2 BLC3 BLC4 BLC5 BLC6 P1 BLEMISH DET CANCEL DEFAULT REMOTE NEXT BACK PRIVACY ZONE OFF ON WHITE BAL ATW1 ATW2 BACKFOCUS OPTION ALARM FUNC ALARM OUT GAMMA 1 0 45 MIRROR ON OFF APERTURE LOW MID HIGH ALARM DELAY ALARM TEXT CHROMA R 0 31 B 0 31 CAMERA ...

Страница 13: ...e turn around the core see figure below Location Core illustration for what camera Power cable LP Y C cable LP MP EIM 0050751G 4 Adjust the back focus The back focus is factory adjusted before delivery for a CS mount lens If re adjustment is necessary please loosen screw set the camera to AES mode see section 7 2 14 2 BACK FOCUS then rotate the back focus wheel until a sharp image appears Tighten ...

Страница 14: ... this mode the camera will change to COLOR mode or B W mode automatically depending on a subject s brightness When GAIN sets OFF auto function can t be selected MONO When set to this mode the camera remains in B W mode COLOR When set to this mode the camera will remain in color mode MANUAL When set to this mode the camera will be switched to color or B W mode manually according to a signal receive...

Страница 15: ...ELAY time for the D N function Move the cursor to the position shown in Fig 3 Use the LEFT RIGHT button to select 0 5 10 15 or 20 sec for delay of DN filter moving timing This setting is only relevant if the D N mode is set to AUTO Info If using the camera together with infrared illumination we recommend using video lenses with special IR coating to prevent a physically based focus shift between d...

Страница 16: ...E ELC mode is for use with fixed iris lenses 7 2 5 SHUTTER Fig 5 SHUTTER This function sets the high speed electronic shutter AUTO to 1 100K sec Move the cursor to the position shown in Fig 5 Using the LEFT RIGHT button select a shutter speed from 1 50 to 1 100K ALC MENU LENS TYPE DC LENS LEVEL BACK ELC MENU LENS LEVEL BACK D N MODE AUTO D N LEVEL HIGH D N DELAY 15 sec EXPOSURE ALC SHUTTER 1 50 GA...

Страница 17: ...or to the position shown in Fig 7 Use the LEFT RIGHT button to choose INT or LL The LL function is available only for camera models supplied with AC power INT The camera is in the internal SYNC mode LL The camera is in the line lock mode you can adjust the phase angle from 0 300 accordingly The default is 0 NOTE For DC power models the SYNC will be set automatically to INT mode D N MODE AUTO D N L...

Страница 18: ...ion window Center 2 Window larger BLC3 Backlight compensation window Top half of the window BLC4 Backlight compensation window Bottom half of the window BLC5 Backlight compensation window Center portion of the upper half BLC6 Backlight compensation window Center portion of the lower half 7 2 9 WHITE BAL Fig 9 WHITE BAL This function is for setting the white balance mode ATW1 ATW2 and manual mode D...

Страница 19: ... red and blue values using the UP DOWN button To exit use the LEFT RIGHT to move the cursor between R and B and press ENTER 7 2 10 GAMMA Fig 10 GAMMA The values which can be selected are 0 45 and 1 0 Move the cursor to the position shown in Fig 10 to set GAMMA value Generally the default value 0 45 is used for CCTV monitor For image processing purposes 1 0 can be selected 7 2 11 APERTURE Fig 11 AP...

Страница 20: ...ximum of 8 blocks can be set on the screen Move the cursor to the position shown in Fig 13 Use ENTER to get into the submenu In the submenu the user can select ON or OFF for the privacy zone and set up to 8 blocks at any position on the screen WHITE BAL ATW2 GAMMA 0 45 APERTURE MID MIRROR OFF PRIVACY ZONE OFF OPTION SET REMODE SET BACK EXIT CANCEL DEFAULT PRIVACY ZONE MENU PRIVACY ZONE OFF BLOCK 1...

Страница 21: ...sure that the lens iris is fully closed Otherwise this action will cause the camera to malfunction 7 2 14 2 BACK FOCUS Press ENTER to perform back focus adjust This function will force the iris of the AI lens to open fully and set the shutter speed temporarily to AUTO for easy back focus adjustment 7 2 14 3 ALARM FUNC Fig 16 Alarm menu ALARM MENU TEXT A B C D E F G H I J K L M N O P Q R S T U V W ...

Страница 22: ...al status of the ALARM output relay NO normally open NC normally closed 7 2 14 5 ALARM DELAY Use the LEFT RIGHT button to select 30 60 90 120 seconds for the timing delay of ALARM operation 7 2 14 6 ALARM TEXT Use ENTER to access the submenu When the alarm input is active the text will be shown on the display 7 2 14 7 CHROMA Use the LEFT RIGHT button to select a value from 1 to 9 7 2 14 8 CAMERA T...

Страница 23: ...mple each camera must have its own specific address Use ADDRESS to set the camera address in a range of 1 255 The camera address must be set correctly before installing the camera Otherwise remote access may not be possible 7 2 15 3 BAUD RATE This function is used to set the camera s remote baud rate in the range from 2400 to 19200 bits per second REMOTE MENU MODEL CCBS1337 LP ADDRESS 001 099 BAUD...

Страница 24: ...via converter CAC0103 V1 6 SIEMENS S When using the camera in unidirectional communication with SIMATRIX NEO based on the SCU protocol 7 2 15 5 SOFT VER SOFT VER indicates the current firmware version on the camera and may vary 7 2 15 6 PATTERN When the PATTERN is set to ON there will be a horizontal color bar picture as shown below on the display The color bar is not standardized and might vary b...

Страница 25: ...E 13 DEFAULT 23 dimensions 8 E EU Directive 6 EXIT 23 exposure 15 F function setting 13 G gain 16 GAMMA 18 M MIRROR 19 N NEXT BACK 23 O operation and storage 7 OPTION 20 ordering data 6 OSD settings 12 P package contents 6 pin assignments 11 privacy zone 19 product specifications 8 R REMOTE 22 S safety precautions 5 shutter 15 SYNC 16 synchronization 16 T Transportation 7 W WHITE BAL 17 white bala...

Страница 26: ...uhe www sbt siemens com fsp 2005 Copyright by Siemens Building Technologies AG Data and design subject to change without notice Supply subject to availability Printed in the Federal Republic of Germany on environment friendly chlorine free paper Document No A24205 A336 B480 Edition 03 2005 ...

Отзывы: