System installation
20
Siemens AG
03.2011
7.2.4
Installation 4 (optional installation box)
1.
Drill the mounting holes for the installation box using the drilling template.
2.
Attach the box to the wall or ceiling using the screws and plastic anchors and
O-rings included in the delivery.
3.
Route the camera connection cable through the cable gland and connect the
power supply and communication lines
to the terminal block (see mounting instructions).
4.
Attach the camera to the installation box using the cap-head screws (M5x20).
5.
Close the box and lock the cover using the cap-head screw M5x10.
6.
Adjust the camera as required using the pan & tilt function. Tighten the grub
screw and the two torx screws to lock the camera in position.
1
2
3
4
5
Fig. 9
Installation 4
1
Plastic anchor Ø 8x40 mm (4x)
2
O-ring (4x)
3
Phillips screw 5x35 mm (4x)
4
Cap-head screw M5x10 mm (1x)
5
Cap-head screw M5x20 mm (4x)
CAUTION
Protection against ingress of solid foreign objects or water
This camera is ingress-protected to IP66 only if installed in accordance with the
instructions in this manual and appropriate waterproofing is applied. For outdoor
use, the mounting base requires waterproofing.
Waterproofing should be made by qualified service personnel or system installers in accordance to the
local requirements.