background image

8 Default settings

Reading MIFARE Classic

UID

Reading MIFARE Plus SL1 – SL3

UID

Reading MIFARE DESFire EV1

UID

Communications mode

OSDP (to change to Wiegand mode remove Jumper 1
and Jumper 3)

Backlight 

Always on (change with 3CT tool)

Bus address

1 (Up to eight are supported)

Wiegand output

26/32/37/56 Bit

Wiegand key PIN burst

4/8 Bits

Light frame

Follows Red, Green LED inputs in Wiegand mode

Tamper/Yellow Connection

Tamper output (change to yellow LED with 3CT tool)

Wiegand heart beat mode

OFF

Time-out for configuration card (keypad backlight
turns off when this timeout expires subsequent to
last keypress)

3 seconds

Activation time-out

30 seconds

Hold-off time for card read

100 milliseconds

Reception for card (time before the same card will
be detected in the field again)

Inactive

Min background illumination

12

Max background illumination

255

Off-line indication

Yes

Buzzer volume for key press

2

Buzzer volume for card read

2

System sound

10

8.1 3CT Tool

To

 

change

 

the

 

default

 

configuration

 

of

 

the

 

reader,

 

use

 

the

 

3CT

 

tool.

 

You

 

can

 

purchase

 

the

 

3CT

 

tool

 

as

 

a

 

separate

 

download.

 

You

 

can

 

use

 

the

 

3CT

 

tool

 

to

 

configure

 

MIFARE

 

Classic

 

and

 

DESFire

 

EV1

 

card

 

formats

 

to

 

be

 

configured

 

along

 

with

 

Wiegand

 

options

 

to

 

be

 

used

 

for

 

the

 

card

 

readers.

 

For

 

further

 

information,

 

please

 

contact

 

your local distributor.

 

The

 

3CT

 

tool

 

configures

 

the

 

format

 

in

 

which

 

user

 

cards

 

are

 

interpreted

 

by

 

the

 

card

 

reader.

 

The

 

3CT

 

tool

 

supports

 

configuration

 

of

 

the

 

following

options: Tamper

 

Output

 

/

 

Yellow

 

Input

 

and

 

Heart

 

beat

 

Mode.

©

 

Siemens

 

2019

25

A-100417-b

15.04.2019

Содержание AR20M-MF

Страница 1: ...Mullion Reader User Manual Document ID A 100417 b Edition date 15 04 2019 ...

Страница 2: ...for any purpose other than for which it was delivered to him MIFARE and MIFARE Classic are trademarks of NXP B V MIFARE DESFire are registered trademarks of NXP B V and are used under license Hereby Siemens Switzerland Ltd declares that this equipment type is in compliance with the following EU Directives for CE marking Directive 2014 30 EU Electromagnetic Compatibility Directive Directive 2014 53...

Страница 3: ... Reverting to standard mode Wiegand 20 5 9 Programming a Reverse mode transmission reader for 26 Bit Wiegand 20 5 9 1 Re programming a reverse mode transmission reader away from 26 Bit Wiegand 21 5 10 Default Configuration Card 21 5 10 1 37 Bit Wiegand 21 6 Closing the reader 22 7 Disassembling the reader 23 7 1 To disassemble the reader 23 7 2 To remove the terminal block 24 8 Default settings 25...

Страница 4: ...10 3 Connecting the reader to ACT in Wiegand mode 32 11 Connecting the reader to SPC 33 ...

Страница 5: ...unication from the reader or the controller they are connected to cannot be compromised The readers are made of hard wearing materials and will endure most weather conditions The readers are easy to mount and can be mounted on a flat surface The readers can be cleaned with most kinds of domestic detergents All readers have a multicolour light frame The AR50M MF has a keypad for PIN code Siemens 20...

Страница 6: ...o 6 cm MIFARE Plus up to 6 cm MIFARE DESfire EV1 EV2 the card must be held to the reader MIFARE Classic up to 6 cm MIFARE Plus up to 6 cm MIFARE DESfire EV1 EV2 the card must be held to the reader Indicators 3 x LED red yellow green 1 x Buzzer Multicolour light frame 3 x LED red yellow green 1 x Buzzer Multicolour light frame Keypad No Yes Operating temperature 40 C to 70 C 40 C to 70 C IP rating ...

Страница 7: ...ion is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Warning Changes or modifications not expressly approved by the party responsible for compliance could void the User s authority to operate the equipment Mullion Reader User Manual Technical ...

Страница 8: ...se consider any additional country specific local laws safety standards or regulations concerning installation operation and disposal of the product Liability claim l Do not make any changes or modifications to the device l Use only spare parts and accessories that have been approved by the manufacturer Siemens 2019 8 A 100417 b 15 04 2019 ...

Страница 9: ...n come through the back 2 Knockouts x 2 7 Tamper base 3 Base 8 Screw for tamper protection 4 Gasket 9 Mounting holes 5 Hook 10 Upper and lower terminal block locations 4 2 Package contents 1 B A terminal block for OSDP and Wiegand lower terminal block 2 R Y T G H terminal block for Wiegand upper terminal block 3 Mounting Tamper screws 4 Cover screw 5 Opening tool Siemens 2019 9 A 100417 b 15 04 20...

Страница 10: ...back of the base gasket item1 in the diagram below Use this hole to feed the cable through the gasket and into the reader base 2 Attach the base to the wall with three screws one in the middle at the top of the base and one in each of the corners at the bottom of the base 1 Cable entry through base gasket 2 Tamper screw 3 Tamper base 3 If tamper protection is required fix the screw item 3 into the...

Страница 11: ...Remove the gasket from the base 2 Identify which of the knockouts the cables should be fed through 3 Use a pliers to pull the knockout away from the base 4 Remove the corresponding knockout on the cover Mullion Reader User Manual Mounting and connecting Siemens 2019 11 A 100417 b 15 04 2019 ...

Страница 12: ...crew as this can damage the tamper base 7 Feed the cables through the opening and reinsert the gasket Follow the instructions for Connecting the cables on the next page Siemens Switzerland Ltd recommend sealing the gap that the knockout creates with a silicon sealant Do this after you have closed the reader Please note that a reader with a removed knockout does not meet the standard for IP 55 Siem...

Страница 13: ...towards the base until it clicks 4 Push the cables back Please note that you must set the Jumpers to configure your application For more information on setting the Jumpers in OSDP mode see Setting the Jumpers for OSDP on page 16 For more information on setting the Jumpers in Wiegand mode see Setting the Jumpers for Wiegand on page 17 On the reverse of the front plate Jumper 3 is used to determine ...

Страница 14: ...mper input Zone Input tamper 1 Tamper input1 G Green LED VA1 Green H Buzzer output System Output1 Buzzer output1 The Tamper output default setting connection may alternatively be configured to provide a Yellow input to the reader The Tamper output Yellow input options are mutually exclusive 1This connection is optional When the tamper output option is configured there is no yellow indication input...

Страница 15: ... Connecting the cables on page 13 Jumper 3 is used to determine EOL By default the reader has EOL ON EOL is always off in Wiegand mode Please note that you must set the Jumpers to configure your application For more information on setting the Jumpers in Wiegand mode see Setting the Jumpers for Wiegand on page 17 Mullion Reader User Manual Mounting and connecting Siemens 2019 15 A 100417 b 15 04 20...

Страница 16: ...Wiegand mode 2 Set OSDP addressing or Wiegand formats 3 Set End Of Line EOL status for the reader This indicates the bottom of the reader 5 5 Setting the Jumpers for OSDP The diagrams below show how to position the Jumpers to get the desired functions from the terminal blocks Note that the EOL is ON for a sole reader or for the last reader on the RS485 bus Jumper 1 Siemens 2019 16 A 100417 b 15 04...

Страница 17: ...d VR50 Mullion readers are configured to transmit standard mode 32 Bit Wiegand 37 Bit Wiegand or 56 Bit Wiegand Some installations may require transmission in Reverse Mode for 26 Bit Wiegand 32 Bit Wiegand or 56 Bit Wiegand If you are adding this reader to an existing Reverse Mode installation you must follow the procedure to program the reader to Reverse Mode Wiegand For more information please r...

Страница 18: ... necessary Procedure Mandatory additional procedure 56 Bit Yes Yes Programming a reader for reverse mode transmission on page 20 No 37 Bit No 32 Bit Yes Yes Programming a reader for reverse mode transmission on page 20 No 26 Bit Yes Yes Programming a reader for reverse mode transmission on page 20 Programming a Reverse mode transmission reader for 26 Bit Wiegand on page 20 The diagrams below show ...

Страница 19: ...ng Reverse Mode installation you must follow the procedure to program the reader to Reverse Mode Wiegand For more information see Programming a reader for reverse mode transmission on the facing page If the existing installation uses 26 Bit Wiegand you must follow an additional procedure to program the reader to transmit in Reverse Mode 26 Bit Wiegand For more information see Programming a Reverse...

Страница 20: ...26 Bit mode 10 Continue with the installation 5 8 1 Reverting to standard mode Wiegand To return the reader to the standard data sequence for Wiegand follow the steps below 1 Remove the Base of the reader from the Front of the reader 2 Power down the reader if connected 3 Connect the Green to the Tamper connection 4 Place Jumper 2 in the lower position 5 Remove Jumper 1 6 Power up the reader The r...

Страница 21: ... the RED indication led flashes each second 6 Power down the reader 7 Disconnect the Red input and the Tamper connection 8 Place Jumper 2 in the appropriate position for the number of Weigand bits upper position for 32 Bit lower position for 56 Bit and remove for 37 Bit 9 Power up the reader l The RED indication LED flashes twice if the reader is configured for 26 Bit Wiegand operation l The GREEN...

Страница 22: ... of the base into the corresponding slot in the front of the reader and slide down 2 Gently press in the bottom of the reader front until the snap lock confirms a secure attachment 3 Screw the cover screw see number 4 in Package contents on page 9 into the bottom of the reader Siemens 2019 22 A 100417 b 15 04 2019 ...

Страница 23: ...assemble the reader 1 Remove the cover screw 2 Insert the opening tool in the slot between the base and the front and push gently upwards 3 Use the opening tool to pull the reader outwards and upwards Siemens 2019 23 A 100417 b 15 04 2019 ...

Страница 24: ...wards to disengage from the hook at the top 7 2 To remove the terminal block 1 Push down gently on the end of the terminal block marked with either BA or RY TGH 2 Tilt the terminal block away from the base Mullion Reader User Manual Disassembling the reader Siemens 2019 24 A 100417 b 15 04 2019 ...

Страница 25: ...rd read 100 milliseconds Reception for card time before the same card will be detected in the field again Inactive Min background illumination 12 Max background illumination 255 Off line indication Yes Buzzer volume for key press 2 Buzzer volume for card read 2 System sound 10 8 1 3CT Tool To change the default configuration of the reader use the 3CT tool You can purchase the 3CT tool as a separat...

Страница 26: ...e visit www freetos org 8 2 Setting burst mode using the keypad The default burst mode is 4 bit This can be changed to 8 bit To change from 4 bit to 8 bit burst 1 Power up the reader while holding the X key The red and green indicators alternately turn on 2 Press the key sequence 1818 to specify that 8 bit burst is required 3 Hold down the key until you hear the two tone affirmative beep 4 To chan...

Страница 27: ... 1 AR50M MF Mullion reader with keypad D Reader 2 AR20M MF Mullion reader E Reader 3 VR40S MF MIFARE Reader with keypad and display The connection between a reader and a Reader Interface Module RIM is as follows RIM DRI ERI VRxx MF 12 V 0V Tx A Rx B SiPass integrated can support both the VR and NGCR readers on the same OSDP bus Siemens 2019 27 A 100417 b 15 04 2019 ...

Страница 28: ... is correctly configured to SiPass integrated This can be tested by holding a card next to the reader A correctly configured reader acknowledges the card according to the SiPass integrated settings Please note that a new reader will always get the next free bus address For example if a reader with bus address 5 is removed and a new reader is installed the new reader gets address 5 9 3 Connecting t...

Страница 29: ...r with keypad D Reader 2 AR20M MF Mullion reader E Reader 3 VR40S MF MIFARE Reader with keypad and display ACTpro 1500 can support both the VR and NGCR readers on the same OSDP bus The connection between a reader and an ACTpro 1500 is as follows ACTpro 1500 VRxx MF 12 24 V OSDP NET 0V OSDP NET A A OSDP NET B B Siemens 2019 29 A 100417 b 15 04 2019 ...

Страница 30: ...utomatically assigns an address to each reader Therefore Jumper 2 should be removed for OSDP operation The serial number of the reader is used to identify and enrol a reader on the system The serial number can be found on a sticker on the reverse of the front cover of the reader bordered in red in the image below Mullion Reader User Manual Connecting the reader to ACT Siemens 2019 30 A 100417 b 15...

Страница 31: ...door name l Record if a reader is an entry or exit reader In the OSDP reader section of ACTEnterprise Software input the following attributes l Name l Serial number l Direction Siemens 2019 31 A 100417 b 15 04 2019 Mullion Reader User Manual Connecting the reader to ACT ...

Страница 32: ...gand see Connecting the reader in Wiegand mode on page 14 If you are connecting an exit reader in Wiegand mode you should wire the D0 from the reader to SENSE on the ACTpro 1500 bordered in red on the image below Mullion Reader User Manual Connecting the reader to ACT Siemens 2019 32 A 100417 b 15 04 2019 ...

Страница 33: ...cting the reader to SPC The SPC connection to a mullion reader is via Wiegand For more detail on connecting via Wiegand see Connecting the reader in Wiegand mode on page 14 Siemens 2019 33 A 100417 b 15 04 2019 ...

Страница 34: ...ta and design subject to change without notice Supply subject to availability Document ID A 100417 b Edition date 15 04 2019 Siemens Switzerland Ltd Gubelstrasse 22 6300 Zug Switzerland www siemens com securityproducts ...

Отзывы: