7. Once the RJ45 cable(s) are attached, align the pins on the rear panel of the access point with the slots on 

the mounting bracket. Press the button on the bottom of the mounting bracket and slide the access point 

into the bracket. Release the button to secure the access point to the mounting bracket, as shown in 

Figure 4

.

Figure 4  

Securing the access point to the mounting bracket 

8. To lock the access point to the mounting bracket, insert the T6 Torx security screw into the hole beside 

the button, located at the bottom of the mount, then tighten the screw until it is snug.

9. After the access point is securely fastened to the mounting bracket, connect the Ethernet cable(s) to the 

appropriate RJ45 coupler port(s) on either side of the mount.

Installing the Mount Housing onto a Wall Box

1. Align the holes on the mounting bracket with the corresponding holes on the wall box. To install this kit 

to a single gang wall box, refer to 

Figure 5

. To install this mount kit to a dual gang wall box, refer to 

Figure 6

. Then, using the 10mm machine screws, fasten the mount housing to the wall box using the 

holes indicated.

Figure 5  

Installing the mounting bracket to a single-gang wall box

Содержание AP-220-MNT-W3

Страница 1: ...nd dual gang wall boxes or mounts to a flat surface such as a wall or ceiling Installing the AP 220 MNT W3 Mount Kit Refer to the steps below for installing your AP 220 MNT W3 Mount Kit Installing the AP 220 MNT W3 to a Flat Surface 1 Optional Remove one or both punch out panel s on the sides of the mounting bracket by pressing firmly as shown in Figure 1 Figure 1 Removing the punch out panels fro...

Страница 2: ...RJ45 coupler s into the housing s located in the upper corner s of the mounting bracket until locked into place in the housing s as shown in Figure 2 Figure 2 Attaching the RJ45 couplers to the mount 5 Remove the RJ45 cable s from the bag and insert the end s into the inner facing port s of the couplers See Figure 3 Figure 3 Inserting the RJ45 cables into the coupler 6 Connect the opposite end s o...

Страница 3: ...o the hole beside the button located at the bottom of the mount then tighten the screw until it is snug 9 After the access point is securely fastened to the mounting bracket connect the Ethernet cable s to the appropriate RJ45 coupler port s on either side of the mount Installing the Mount Housing onto a Wall Box 1 Align the holes on the mounting bracket with the corresponding holes on the wall bo...

Страница 4: ...e pins on the rear panel of the access point with the slots on the mount housing Press the button on the bottom of the mount housing and slide the access point into the slots Release the button to secure the access point to the mounting bracket See Figure 7 Figure 7 Securing the access point to the mounting bracket 4 To lock the access point to the mounting bracket insert the T6 Torx security scre...

Страница 5: ...AP 220 MNT W3 Mount Kit Mounting Template 0511858 01 October 2015 1 Use the image below as template to mount the AP 220 MNT W3 Mount Kit 23 0 mm 139 90 mm 83 0 mm All mounting holes have a 4 mm diameter ...

Отзывы: