C53000-B1100-C602-1
7XV5810 0xA00
Operating Instructions
Seite 11 von 20
2 Technical
Data
2.1 Power supply 7XV5810 0BA00 (24 V)
Input
Power supply (V
aux
) – Direct-current voltage (DC)
24 V to 250 V (±20 %)
Ripple allowed for the DC input voltage
15 %
Power input
12 W
Maximum inrush current at
≤
110 V
< 15 A
Maximum inrush current at 220 V to
300 V
≤
22 A; after 250 µs: < 5 A
Degree of efficiency
> 50 % at nominal load
Power supply (V
aux
) – Alternative current (AC)
60 V to 230 V (±20 %),
45 Hz to 65 Hz
Higher harmonics allowed
2 kHz
Maximum inrush current at
≤
115 V
< 15 A
Maximum inrush current at 230 V
≤
22 A; after 250 µs: < 5 A
Power input
25 VA
Output
Connection 2-pole
terminal
Rated output current
Max. 250 mA
Behavior in case of short-circuit: mains
buffering
permanent
Power supply failure
At least 50 ms at nominal load
Status display of the output voltage
1 green operating LED
Rated output voltage
DC 24 V; Imax = 125 mA
(at V
aux
= DC 24 V to 35 V)
DC 24 V; Imax = 250 mA
(at V
aux
= DC 35 V to 250 V or AC 60 V
to 230 V)