Security recommendations
SCALANCE W778-1 / W738-1
18
Operating Instructions, 03/2022, C79000-G8976-C450-07
The following is a list of all available Layer 2 services through which the device can be
accessed.
The table includes the following columns:
•
Layer 2 service
The Layer 2 services that the device supports
.
•
Default status
The default status of the service (open or closed).
•
Service configurable
Indicates whether the service can be configured via WBM / CLI.
Layer 2 service
Default
status
Service
configurable
DCP
Open
✓
LLDP
Open
✓
RSTP
Open
✓
iPRP
Open
✓
MSTP
Closed
✓
SIMATIC NET TIME
Closed
✓
Содержание 6GK5738-1GY00-0AA0
Страница 8: ...Introduction SCALANCE W778 1 W738 1 8 Operating Instructions 03 2022 C79000 G8976 C450 07 ...
Страница 10: ...Safety notices SCALANCE W778 1 W738 1 10 Operating Instructions 03 2022 C79000 G8976 C450 07 ...
Страница 62: ...Maintenance and cleaning SCALANCE W778 1 W738 1 62 Operating Instructions 03 2022 C79000 G8976 C450 07 ...
Страница 72: ...Technical specifications SCALANCE W778 1 W738 1 72 Operating Instructions 03 2022 C79000 G8976 C450 07 ...