Configuration
4.11 Maintenance
SIMATIC CC7
114
Operating Instructions, 10/2019, C79000-G8976-C503-02
4.11.3
User
Note
Loss of user data
Note changed or newly assigned user names and passwords.
When you lose the user data of the administrator, you no longer have access to the WBM.
When losing the login data, you only have access to the WBM by resetting the device to the
factory settings. This is associated with a loss of data.
For the preset standard user data for initial login, see section Logging into the WBM
(Page 53).
Permitted length of the user name: 4...64 characters
Note
Changing the password
For security reasons, the user name and password preset at the factory must be changed at
the first login.
Passwort rules
Newly assigned user passwords must meet the following requirements:
●
Minimum length: 8 characters
●
At least 1 lowercase letter
●
At least 1 uppercase letter
●
At least 1 number
●
At least one of the following special characters (ASCII 0x21..0x7E):
! " # $ % & ' ( ) * + , - . / : ; < = > ? @ [ \ ] ^ _ ` { | } ~
Roles and rights
An administrator can be set up.
The administrator has the rights to change all data that is accessible in the WBM.