Pin
Signal name
Type
Meaning
7
KT-IN7
I
Customer key 7
8
KT-IN8
I
Customer key 8
9
M
V
Ground
10
M
V
Ground
11
M
V
Ground
12
M
V
Ground
13
KT-OUT1
O
24 V output 1
14
KT-OUT2
O
24 V output 2
15
KT-OUT3
O
24 V output 3
16
KT-OUT4
O
24 V output 4
17
KT-OUT5
O
24 V output 5
18
KT-OUT6
O
24 V output 6
19
KT-OUT7
O
24 V output 7
20
KT-OUT8
O
24 V output 8
KT-IN: customer keys input; KT-OUT: customer keys output
Table 5-5
Assignment of connector X516
Pin
Signal name
Type
Meaning
1
KT-IN9
I
Customer key 9
2
KT-IN10
I
Customer key 10
3
KT-IN11
I
Customer key 11
4
KT-IN12
I
Customer key 12
5
KT-IN13
I
Customer key 13
6
KT-IN14
I
Customer key 14
7
KT-IN15
I
Customer key 15
8
KT-IN16
I
Customer key 16
9
M
V
Ground
10
M
V
Ground
11
M
V
Ground
12
M
V
Ground
13
KT-OUT9
O
24 V output 9
14
KT-OUT10
O
24 V output 10
15
KT-OUT11
O
24 V output 11
16
KT-OUT12
O
24 V output 12
17
KT-OUT13
O
24 V output 13
18
KT-OUT14
O
24 V output 14
19
KT-OUT15
O
24 V output 15
20
KT-OUT16
O
24 V output 16
Connecting
5.1 interfaces
ONE MCP Part 1: MCP xxxx
Equipment Manual, 07/2020, A5E50324729B AA
37
Содержание 6FC5303-0AP0 Series
Страница 16: ...Description 2 3 Rating plate ONE MCP Part 1 MCP xxxx 16 Equipment Manual 07 2020 A5E50324729B AA ...
Страница 60: ...Technical data 8 3 Recycling and disposal ONE MCP Part 1 MCP xxxx 60 Equipment Manual 07 2020 A5E50324729B AA ...
Страница 64: ...Safety symbols ONE MCP Part 1 MCP xxxx 64 Equipment Manual 07 2020 A5E50324729B AA ...
Страница 66: ...Index ONE MCP Part 1 MCP xxxx 66 Equipment Manual 07 2020 A5E50324729B AA ...