background image

 

 

Installation Instructions 

Document No. 538-588 

Rev. 3, December, 2001 

Fiber Optic Hub 

 

 

 

Page 1 of 3 

Product Description 

The Fiber Optic Hub concentrates four fiber lines 
into one logical trunk for the fiber building level 
network (BLN) or the floor level network (FLN). The 
BLN and FLN trunk electrical signals are converted 
into light energy at the remote sites by Fiber Optic 
Interfaces. This device is designed to work at 
speeds of 300 bps to 230K bps, with a link budget of 
11.5 dB.  

The Fiber Optic Hub converts light energy to 
electrical signals and back to light energy for the 
outgoing fibers, which connect to the remote site 
Fiber Optic Interfaces’ receive ports. The hub also 
converts electrical signals to an Inter-Hub RS-485 
bus. This bus is used for inter-connecting multiple 
hubs at one location, for a maximum of 32 hubs. 

The inter-hub trunk connection uses the standard 
three-terminal, removable connector found on many 
Siemens products. The connection can also be used 
to obtain a local BLN or FLN for the building in which 
the hub is installed. 

The Fiber-Optic Hub is housed in a 1.5” × 7.3” × 6” 
metal enclosure. It contains one power input 
receptacle, eight fiber ports (four transmit and four 
receive), and a three-position trunk port (refer to 
Figure 2). The hub is powered by a 6 Vdc external 
power pack (included). All circuits are supervised 
and power limited. There are no internal settings or 
user-serviceable parts. ST style port connectors are 
included with the hub. 

FIBER OPTIC HUB

Power

Channel 1

Channel 2

Channel 3

Channel 4

NT0211R2

TX

RX

TX

RX

TX

RX

TX

RX

I

 

Figure 1.  Fiber Optic Hub (Front View). 

NT0222R1

TX2

RX2

TRUNK

S –

+

Operating Temp. 0-50 C (32-122 F)

Power

6Vdc

350 ma

538-745 Fiber Optic Hub

TX1

RX1

TX4

RX4

TX3

RX3

POWER INPUT

RECEPTACLE

TRUNK

 PORT 

RECEIVE 

PORT 

TRANSMIT

PORT 

 

Figure 2.  Fiber Optic Hub (Rear View). 

Product Numbers 

Description Product 

Number 

Four Channel Fiber Optic Hub with 
ST port connectors 

538-745 (115 Vac) 
538-745E (230 Vac) 

115 Vac 60 Hz (14W) input 6 Vdc 
1200 mA output power pack for 
use with P/N 538-745 

538-746 

230 Vac 50 Hz (14W) input 6 Vdc 
1000 mA output power pack for 
use with P/N 538-745E 

538-747 

 

 

 

CAUTION:  Use only the plug-in 
transformer shipped with this device. 

120 Vac transient protected duplex 
outlet for 538-745 (not included) 

529-804 

Three 250V Three Metal Oxide 
Varistors (MOVs) included with P/N 
538-745E 

527-969 

Optional wall mounting kit (7”) 

538-709K 

Optional rack mounting kit (7”) 

538-717K 

 

Required Tools 

• 

19-inch rack position available if using the 
rack mounting kit 

• 

Small slotted screwdriver 

• 

Wire cutters or wire strippers 

• 

7/16-inch (11.1mm) nut driver 

Expected Installation Time 

15 minutes 

 

Отзывы: