background image

3ZX1012-0VL40-2FA1

5

Ø 4.5

65

65

Ø 42...50

11b

X

2.5

Y

7

11c

3VL9400-3HF04/HG04

3VL9400-3HF05/HG05

3VL9400-3HF04/HG04
2.4 Nm

3VL9400-3HF05/HG05
1.3 Nm

44

88

44

Ø 64

2.5

7

88

4 x Ø 5.5

Y

X

11a

3VL9400-3HF05

3VL9400-3HG05

3VL9400-3HF04
3VL9400-3HG04

101

Z

X

40

126.5

22.5

2.

5

300.0 MAX - 60.0 MIN

101.5

162.5

186.5

12

3VL9400-

3HF05/HG05

3VL9400-

3HF04/HG04

3VL9400-3HF04/HG04: 6 Nm

3VL9400-3HF05/HG05: 2.8 Nm

3VL9400-3HF04/HG04: 6 Nm
3VL9400-3HF05/HG05: 2.8 Nm

3VL9400-3HF04

/HG04: 6 Nm

3VL9400-3HF05

/HG05: 1.3 Nm

3VL9400-3HF04/3HG04: 490 MAX - 230 MIN
(312 MIN with Support Bracket)

3VL9400-3HF05/3HG05: 466.5 MAX - 230 MIN
(312 MIN with Support Bracket)

D > 100 mm 

P

D

Y

Siemens Automation Products

Содержание 3VL9400-3HF0 Series

Страница 1: ...rité de fonctionnement de l appareil n est garantie qu avec des composants certifiés Español Italiano Português Leer y comprender este instructivo antes de la instalación operación o mantenimiento del equipo Leggere con attenzione queste istruzioni prima di installare utilizzare o eseguire manutenzione su questa apparecchiatura Ler e compreender estas instruções antes da instalação operação ou man...

Страница 2: ...tagem TR Montaj için gerekli aletler РУ Инструменты необходимые для монтажа 中文 安装所需工具 DE Lieferumfang EN Quantity of delivery FR Composition de la fourniture ES Alcance del suministro IT Configurazione di fornitura PT Âmbito do fornecimento TR Teslimat hacmi РУ Комплект поставки 中文 供货范围 3VL9400 3HE0_ 3VL9400 3AT10 EMS OFF ON 3VL9400 3AS10 EMS OFF ON cal ISO 6789 1 3VL9400 3AU10 EBS ON OFF 3VL9400 ...

Страница 3: ...3ZX1012 0VL40 2FA1 3 3 3VL9715 8HA00 E01 3VL9400 3H_0_ E01 OK 4 0 5 Nm E01 2b Siemens Automation Products ...

Страница 4: ... Déclenché ES Disparado IT Sganciato PT Disparado TR Çözülmüs durum РУ Разомкнуто 中文 断开 Tripped 6 7 9 DE Auslösen EN Trip FR Déclencher ES Disparar IT Sganciare PT Disparar TR Çözme РУ Размыкание 中文 脱扣 2 1 ON I RESET clac 2 1 ON I RESET clac 10 TRIP TEST TRIP OK 7 10 ...

Страница 5: ...400 3HG04 101 Z X 40 126 5 22 5 2 5 300 0 MAX 60 0 MIN 101 5 162 5 186 5 12 3VL9400 3HF05 HG05 3VL9400 3HF04 HG04 3VL9400 3HF04 HG04 6 Nm 3VL9400 3HF05 HG05 2 8 Nm 3VL9400 3HF04 HG04 6 Nm 3VL9400 3HF05 HG05 2 8 Nm 3VL9400 3HF04 HG04 6 Nm 3VL9400 3HF05 HG05 1 3 Nm 3VL9400 3HF04 3HG04 490 MAX 230 MIN 312 MIN with Support Bracket 3VL9400 3HF05 3HG05 466 5 MAX 230 MIN 312 MIN with Support Bracket D 10...

Страница 6: ...e PT Mais informações encontram se no manual 3VL na Internet sob www siemens com lowvoltage manuals 3VL somente em alemão e em inglês TR Diğer bilgileri internetde 3VL el kitabında bulabilrsiniz www siemens com lowvoltage manuals 3VL yanliz almanca ve ingilizce РУ Дальнейшую информацию Вы можете найти в инструкции по использованию 3VL в интернете по адресу www siemens com lowvoltage manuals 3VL то...

Отзывы: