Storing indoors
NOTICE
Damage caused as a result of outdoor storage
Storing the machine outdoors can result in it being damaged.
● Ensure that the machine is only stored in areas that comply with the following conditions.
● Store the motor in an area that meets the following criteria:
– The room must be dry, dust-free, frost-free and vibration-free. The relative humidity of
the air should be less than 60%. The temperature should not drop below ‑15 °C in
accordance with EN 60034-1.
– The room must be well ventilated.
– The room must provide protection against extreme weather conditions.
– The air in the room must not contain any harmful gases.
● Protect the motor from shocks and humidity.
● Cover the motor properly.
● Avoid contact corrosion:
– Every three months, remove the shipping brace. Rotate the shaft extension by hand.
– Then reattach the rotor shipping brace.
Protection against humidity
● If a dry storage area is not available, then take the following precautions:
– Wrap the machine in a material that absorbs moisture. Then pack the machine in an
airtight film.
– Include several bags of desiccant in the seal-tight packaging. Check the desiccant and
replace as required.
– Place a humidity meter in the airtight packaging that indicates the level of humidity inside
it.
– Inspect the motor regularly.
See also
Protect the cooling water system of water-cooled motors (Page 45)
Preparations for use
4.13 Transport and storage
SIMOTICS M-1PH8 1PH818., 1PH822.
42
Operating Instructions 07/2016
Содержание 1PH818
Страница 2: ...18 07 2016 14 04 V14 00 ...
Страница 12: ...Introduction SIMOTICS M 1PH8 1PH818 1PH822 12 Operating Instructions 07 2016 ...
Страница 28: ...Description SIMOTICS M 1PH8 1PH818 1PH822 28 Operating Instructions 07 2016 ...
Страница 48: ...Preparations for use 4 14 Converter operation SIMOTICS M 1PH8 1PH818 1PH822 48 Operating Instructions 07 2016 ...
Страница 82: ...Electrical connection 6 4 Auxiliary circuits SIMOTICS M 1PH8 1PH818 1PH822 82 Operating Instructions 07 2016 ...
Страница 100: ...Operation 8 10 Faults SIMOTICS M 1PH8 1PH818 1PH822 100 Operating Instructions 07 2016 ...
Страница 126: ...Spare parts 10 9 Speed encoder type 1PH818 1PH822 SIMOTICS M 1PH8 1PH818 1PH822 126 Operating Instructions 07 2016 ...
Страница 136: ...Quality documents SIMOTICS M 1PH8 1PH818 1PH822 136 Operating Instructions 07 2016 ...
Страница 163: ...D 3 Operating instructions of the EC external fan SIMOTICS M 1PH8 1PH818 1PH822 Operating Instructions 07 2016 163 ...
Страница 197: ...AA Manual STROMAG Break AC Manual Ziehl Abegg external fan ...
Страница 198: ...Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY www siemens com drives ...