Electrical connection
8.3 System integration
1FW6 High Speed built-in torque motors
254
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
Connection assignment
Table 8- 6
Power connection for torque motor
Converter
Torque motor/stator
U2
U
V2
V
W2
W
For information on connecting the power, also refer to the diagrams relating to "System
integration". The rotor rotates clockwise if the torque motor is connected to phase sequence
U, V, W. See "Defining the direction of rotation (Page 38)".
8.3.8
Signal connection
No direct connection of the temperature monitoring circuits
WARNING
Risk of electric shock when incorrectly connecting the temperature monitoring circuit
In the case of a fault, circuits Temp-S and Temp-F do not provide safe electrical separation
with respect to the power components.
•
Use, for example, the TM120 or the SME12x to connect the Temp-S and Temp-F
temperature monitoring circuits. You therefore comply with the directives for safe
electrical separation according to EN 61800-5-1 (previously safe electrical separation
according to EN 50178).
Correctly connecting temperature sensors
NOTICE
Motor destroyed as a result of overtemperature
The motor can be destroyed as a result of overtemperature if you do not correctly connect
the temperature sensors.
•
When connecting temperature sensor cables with open conductor ends, pay attention to
the correct assignment of conductor colors.
Содержание 1FW6092-2PC15-6AB3
Страница 1: ...1FW6 High Speed built in torque motors ...
Страница 2: ......
Страница 10: ...Introduction 1FW6 High Speed built in torque motors 8 Configuration Manual 01 2020 6SN1197 0AE03 0BP3 ...
Страница 140: ...Configuration 5 4 Mounting 1FW6 High Speed built in torque motors 138 Configuration Manual 01 2020 6SN1197 0AE03 0BP3 ...
Страница 298: ...Index 1FW6 High Speed built in torque motors 296 Configuration Manual 01 2020 6SN1197 0AE03 0BP3 ...
Страница 299: ......
Страница 300: ......