![Siemens Mobile TC45 Скачать руководство пользователя страница 182](http://html.mh-extra.com/html/siemens-mobile/tc45/tc45_manual_1266136182.webp)
TC45 AT Command Set
8.3 AT+CREG
s
m
obile
TC45_ATC_V02.02
Page 182 of 461
4/16/04
Confidential / Released
Command Description
Read command returns the URC presentation mode
and an integer
that shows the registration sta-
tus of the ME. The location information elements
and
are returned only when
=2 and ME is
registered to the network.
Use the write command to select the type of URC. Two types of URCs are available:
[,
Parameter Description
0
(&F)
disable URCs
1
enable URC +CREG:
to report status of network registration
2
enable URC +CREG:
] to report status of network regis-
tration including location information. Please note that optional parameters will
not be displayed during call.
0
Not registered, ME is currently not searching for new operator
There is a technical problem. User intervention is required. Yet, emergency
calls can be made if any network is available. Probable causes.
• No SIM-Card available
• No PIN entered
• No valid Home PLMN-Entry found on the SIM
1
Registered to home network
2
Not registered, but ME is currently searching for a new operator.
The ME searches for an available network. Failure to log in until after more than
a minute may be due to one of the following causes:
• No network available or insufficient Rx level.
• The ME has no access rights to the networks available.
• Networks from the SIM list of allowed networks are around, but login fails
due to one of the following reasons:
- #11 ... PLMN not allowed
- #12 ... Location area not allowed
- #13 ... Roaming not allowed in this location area
After this, the search will be resumed (if automatic network search is
enabled).
• The Home PLMN or an allowed PLMN is available, but login is rejected by
the cell (reasons: Access Class or LAC).
If at least one network is available, emergency calls can be made.
3
Registration denied
• If automatic network search is enabled:
Authentication or registration fails after Location Up-date Reject due to one
of the following causes:
- #2 ... IMSI unknown at HLR
- #3 ... Illegal MS
<n>
(num)(&W)(&V)
<stat>
(num)(&V)