SIELCO srl
- Via Toscana, 57/59 - 20090 BUCCINASCO (Mi) - ITALY - tel. 02 - 45713300 - www.sielco.org
EXC/RTX19 - USER & MAINTENANCE MANUAL - rev.1.5 - 05/16
Page 39
SETUP CONTROL
LOCAL & REMOTE
REMOTELY LOCKED
PRESET TO LOCAL!
FREQ. 2470.175 MHz
F= -55dBm T=+ 1.2kHz
RECEIVER SETUP MENU
Field #21: Local/Remote control setup
The apparatus may be controlled either locally from the front panel or remotely from the I/O
lines and RS232 serial port. It is possible to permit concurrently control as default shown (remote
I/O lines may be prevalent in case of any function disable) or only local or by remote. So the
highlighted line may be changed in:
LOCAL ONLY
or
REMOTE ONLY
In case the apparatus is remotely locked, any temptative to access to setup menu will show the
following message:
Pushing twice "Enter" on the control jog will select the "SETUP CONTROL" menu and highlight the
upper field ("REMOTELY LOCKED") permitting to change it to "LOCAL & REMOTE" or "LOCAL
ONLY" if required.
Field #22: Frequency setup
Here it is possible to preset the received frequency in a similar manner as in the transmitters.
In the receiver the frequency is changed in real time with editing, whenever possible.
The bottom line shows the associated received field and center tuning. Bear in mind that very
often major frequency changes requires several seconds to be effective and during this time the
infomation on the bottom line is meaningless.