Siegenia Aeruotube AZ smart Скачать руководство пользователя страница 23

Original operating instructions 

AEROTUBE

11.2016

23

EU Declaration of Conformity with regard to CE marking

For our product AEROTUBE, we confirm that the general safety of the defined product, in accordance with Directive 

2001/95/EC,

 

is compliant with the relevant protection requirements which are laid down in the Council Directives about electrical and electronic 
products.
The following listed test standards, which are harmonised in the relevant directives, have been employed for the evaluation:

a)

2014/30/EC EMC Directive

EN 55014-1:2006+A1:2009+A2:2011
EN 55014-2:1997+A1:2001+A2:2008
EN 61000-3-2:2014
EN 61000-3-3:2013

b)

2014/35/EC Low voltage directive

EN 60335-1:2012+A11:2014
EN 62233:2008

c)

2014/53/EC RED Directive

c1) Electromagnetic compatibility

EN 301489-1, V.1.9.2
EN 301 489-17, V.2.2.1
EN 61000-3-2:2014
EN 61000-3-3:2013

c2) Electrical safety - Establishment of information technology

EN 60950-1:2006+A11:2009+A12:2011+A1:2010+A2:2013

c3) Safety of persons in electromagnetic fields (10 MHz to 300 GHz)

EN 62479:2010

c4) Radio spectrum matters - data transmission devices in 2.4- GHz-ISM-Band

EN 300 328 V1.9.1

d)

2006/42/EC Machinery Directive

EN 12100:2010 Risk assessment

e)

2011/65/EU RoHs

EN 50581:2012 Technical documentation on the evaluation of electrical and electronic devices with 
reference to the restriction of hazardous substances

This declaration is responsible for the manufacturers / importers based in the European Union submitted by:

SIEGENIA-AUBI KG
Hardware and ventilation technology
Duisburger Straße 8
57234 Wilnsdorf

Siegen, 2016-10-25

Содержание Aeruotube AZ smart

Страница 1: ...ventilator with optional supply and exhaust air function heat recovery and temperature humidity sensor AEROTUBE WRG smart AEROTUBE AZ smart Window systems Door systems Comfort systems ORIGINAL OPERAT...

Страница 2: ...delivery equipment 5 Installation 6 Unit function 11 Operation general 12 Operation via button on the device 13 Operation via smartphone or tablet 13 Care and maintenance 14 Accessories 19 Rectificati...

Страница 3: ...with corrosive or explosive atmospheres dust vapour or gas The unit is not suitable for use in swimming pools and or damp locations The AEROTUBE must be mounted in a vertical position Mounting on incl...

Страница 4: ...All pole safety isolation is required if the customer is routing the mains cable Current local regulations such as those of the VDE in Germany must be observed Relevant country specific regulations w...

Страница 5: ...accumulator 9 Ventilation pipe 160 10 Bag of screws 4 screws and dowels 11 Translation of the original operating instructions 12 Weather grille optional see accessories page 19 Function Heat recovery...

Страница 6: ...l objects Air conditioning units Wireless devices e g radio telephones baby monitors Bluetooth loudspeakers etc WLAN networks on the same wireless channels e g the neighbour s WLAN router If energy ca...

Страница 7: ...discharging outwards the hole must have an incline of 0 5 2 However the slope must not exceed 3 as this would make it impossible to remove the pipe inset from the ventilation pipe for maintenance pur...

Страница 8: ...iginal operating instructions 11 2016 5 Shorten pipe 6 Insert pipe Attention The pipe must be at least 270 mm long X X 7 Insulate pipe according to requirement 8 Seal pipe Inside airtight seal Outside...

Страница 9: ...ng instructions AEROTUBE 11 2016 9 9 Push complete pipe inset with mounting cover into the pipe 10 Plaster the wall 11 Remove front panel 12 Remove electronics cover 13 Remove mounting cover 14 Positi...

Страница 10: ...016 15 Fix filter casing into place 16 Connect mains cable 4x N L1 PE 17 Clip electronic cover into place 18 Connect axial ventilator 19 Clip front panel into place 20 Position the weather grille scre...

Страница 11: ...rt The warm exhaust air is absorbed by the ceramic heat accumulator in supply and exhaust air operation The stored heat is transferred to the supply air and thus proceeds into the room preheated Opera...

Страница 12: ...LED 3 lights up green Automatic mode Blower level 1 LED 2 lights up green LED 3 lights up green Automatic mode Blower level 2 LED 1 lights up green LED 2 lights up green LED 3 lights up green Automat...

Страница 13: ...timers can be programmed free definition of starting time running time week days mode of operation and blower performance Filter change indicator and reset of the filter change indicator after filter...

Страница 14: ...e AEROTUBE do not allow liquids to get inside the unit Never use cleaning agents that are aggressive or contain solvents or sharp edged objects as these may damage the surfaces of the casing Never cle...

Страница 15: ...to pipe inset falling out Ensure that the pipe inset does not fall down Proceed with caution 1 Remove front panel 2 Remove complete pipe inset 3 Open pipe inset Attention Do not bend the retaining cl...

Страница 16: ...1 2016 4 Remove filter and ceramic heat accumulator 5 Dispose of the old filter 6 Clean ceramic heat accumulator and leave to dry 7 Position ceramic heat accumulator in pipe inset 8 Clamp new filter b...

Страница 17: ...ting instructions AEROTUBE 11 2016 17 10 Push complete pipe inset into pipe 11 Connect axial ventilator 12 Clip front panel into place Attention The cable outlet in the front panel must be on the slid...

Страница 18: ...ns 11 2016 Filter replacement AEROTUBE AZ smart 1 Remove front panel 2 Remove filter 3 Dispose of the old filter 4 Insert new filter 5 Clip front panel into place Attention The cable outlet in the fro...

Страница 19: ...ion AEROTUBE shows no reaction when key is pressed No power supply Check power supply Wiring wrong defective or cable defective Have the wiring checked by a qualified electrician Power supply defectiv...

Страница 20: ...SEV Energy efficiency class SEV class according to climatic zone warm average cold 17 62 kWh m a E 42 15 kWh m a A 84 96 kWh m a A 10 99 kWh m a E 25 36 kWh m a C 50 44 kWh m a A d Type WLA ZLA WLA E...

Страница 21: ...Original operating instructions AEROTUBE 11 2016 21 Dimensions 63 259 279 259 279...

Страница 22: ...rtly dismantled and the defect is due to the changes made Exclusion of liability The product and its components are subject to stringent quality controls As a result they function reliably and safely...

Страница 23: ...14 EN 62233 2008 c 2014 53 EC RED Directive c1 Electromagnetic compatibility EN 301489 1 V 1 9 2 EN 301 489 17 V 2 2 1 EN 61000 3 2 2014 EN 61000 3 3 2013 c2 Electrical safety Establishment of informa...

Страница 24: ...85 4861080 China Phone 86 316 5998198 France Phone 33 3 89618131 Germany Phone 49 271 39310 Great Britain Phone 44 2476 622000 Hungary Phone 36 76 500810 Italy Phone 39 02 9353601 Poland Phone 48 77 4...

Отзывы: