H39.WANS012EN-01
07.2019
3/20
Assembly instructions
Basic.mounting.box
AERO
1
Target group of this documentation
•
This.documentation.is.intended.for.use.by.
specialists.
•
All.instructions.concerning.assembly,.installation.
and repairs described in this document are to be
performed.exclusively.by.experienced.professionals.
with.training.and.practice.in.the.installation,.
commissioning,.servicing.and.maintenance.of.
decentralised.ventilation.units.
2
Intended use
•
Use.the.AEROVITAL.ambience.exclusively.for.the.
ventilation.of.closed.rooms.(kitchen,.bathroom,.
living.rooms.and.bedrooms).
• AEROVITAL ambience is not suitable for
dehumidification.(e.g..for.the.drying.of.new.
buildings).
•
The.unit.must.always.be.installed.by.an.experienced.
specialist,.in.accordance.with.the.installation.and.
planning.documents.of.SIEGENIA..The.installation.
instructions.in.this.document.must.be.complied.
with.at.all.times.
•
Be.sure.to.mount.the.supplied.SIEGENIA.weather.
grille.for.the.protection.of.the.unit.from.the.outer.
side.
• Do not install the unit in contaminated rooms and
ensure that no hazardous substances can be drawn
in.
•
The.unit.is.not.suitable.for.use.in.swimming.pools.
and/or.damp.locations.
•
AEROVITAL.ambience.must.be.mounted.in.a.vertical.
position..Mounting.on.inclines.(e.g..walls.and.
ceilings),.is.not.permissible.
•
If.the.unit.is.to.be.used.in.a.room.with.a.heating.unit.
that.draws.air.from.the.room,.prior.authorisation.
must.be.obtained.from.the.proper.authorities,.such.
as.the.officially.appointed.district.chimney.sweep.
• Only operate and/or store the AEROVITAL ambience
at.temperatures.between.‒.15°C.and.+40°C.
•
Use.the.unit.only.with.original.accessories.from.
SIEGENIA.
•
Comply.with.the.safety.regulations.for.operating.
electrical.equipment.and,.if.necessary,.for.ladders,.
steps.and.work.overhead.or.at.certain.heights.
• Use the unit only when it is in a technically sound
condition..
• Do not modify the unit's components in any way.
• Please do not put any objects on top of the unit.
• Do not use the device as a seat.
•
Make.sure.that.air.can.flow.in.and.out.at.the.two.
outer.sides.without.impedance..Do.not.hang.any.
textiles.or.paper.or.similar.items.over.the.air.inlet.
and outlet ports and do not place any objects
directly.in.front.of.or.next.to.the.unit..Do.not.insert.
any.objects.into.the.openings.of.the.unit.
• Do not remove any covers or unit components that
are.not.defined.in.the."Maintenance".chapter..Do.
not.remove.the.cover.of.the.connecting.clamps.
inside the unit.
•
Please.make.sure.that.the.unit.is.not.switched.off.
for.a.longer.period.(several.days).in.order.to.enable.
minimum.ventilation.and.to.prevent.nesting.of.
insects.
•
The.unit.must.be.checked.by.a.specialist.in.the.
event of a fault.