Intended use

• 

The AEROMAT VT is intended for installation in the exterior windows/walls of permanent structures in accordance with 
our installation and design documents as well as the specifications of our assembly instructions and is only suitable for the 
ventilation of enclosed rooms.

• 

Do not use the AEROMAT VT in environments with corrosive or explosive atmospheres (dust, vapour or gas).

• 

If the AEROMAT VT is to be used in a room with a heating unit that draws air from the room, prior authorisation must be 
obtained from the proper authorities, such as the officially appointed district chimney sweep. Intended use requires that 
any combustion air lines and exhaust gas systems of solid fuel heating units must be able to be shut off.

• 

Only operate and/or store the AEROMAT VT at temperatures between -15 °C and +40 °C.

• 

Use the AEROMAT VT only with genuine accessories from SIEGENIA.

• 

Use the AEROMAT VT only when it is in a technically sound condition. Do not modify the unit's components in any way.

• 

Ventilation openings must be kept free and must not be blocked by other equipment, furniture or objects.

• 

If the AEROMAT VT is fitted with filters, you must make sure that these cannot become the source of elements that are 
odorous and harmful to health; this also includes regular inspection and replacement of filters.

• 

In the event of a fault, only have the AEROMAT VT repaired by experienced specialists with training and practice in the 
repair of ventilation units.

Safety notices

RS Type

• 

This unit can be used by children aged 8 and above as well as by people with physical, sensory or mental difficulties or 
with a lack of experience and knowledge as long as they are supervised or have been instructed in how to use the unit 
safely and understand the resulting risks. Children must not play with the unit. Cleaning and user maintenance must not be 
carried out by children without supervision.

• 

Insert the Euro plug of the network connection cable into a suitable 230-V AC mains power supply only.

• 

If the network connection cable is damaged, it may only be replaced by SIEGENIA, its customer service department or 
an electrician.

• 

Work on a 230-V AC mains power supply may only be performed by a qualified electrician.

• 

All work on the 230-V AC mains power supply must be carried out in compliance with the current German VDE 
regulations (e.g. VDE 0100) and any relevant country-specific requirements.

• 

All-pole safety isolation should be used when fitting the network connection cable on-site.

• 

Should a solid object or any liquid get inside the unit, stop operation immediately and disconnect the AEROMAT VT from 
the mains power supply:
-  Check whether the AEROMAT VT has become damaged.
-  Have the unit repaired by a specialist, if necessary

Содержание AEROMAT VT.

Страница 1: ...Install ation and operating instructions AEROMAT VT Sound absorbing ventilator Window hardware Door hardware Sliding door hardware Ventil ation technology Building technology Ventil ation technology...

Страница 2: ......

Страница 3: ...and operating instructions AEROMAT VT Last update 02 2015 3 Intended use 4 Safety notices 4 Installation 5 Power supply 8 Function 9 Operation 9 Care and maintenance 11 Technical data 14 Dimensions 14...

Страница 4: ...and harmful to health this also includes regular inspection and replacement of filters In the event of a fault only have the AEROMAT VT repaired by experienced specialists with training and practice...

Страница 5: ...on the quality of the air being drawn in The maximum permissible area load is 1 000 kg per running metre of ventilator length Installation options Installation in the window sill Concealed installatio...

Страница 6: ...uids can get inside the weather grille before the outside window sill is installed AEROMAT VT and cover the weather grille with film as shown in illustration 4 Install the AEROMAT VT in its intended i...

Страница 7: ...EGENIA aluminium mounting brackets AEROMAT VT with 911 CW weather grille AEROMAT VT with 911 HW weather grille Dimension Meaning a Mounting area for bracket b Screw and drilling area e g for wall plug...

Страница 8: ...or unscrew the security devices Important If the AEROMAT VT is connected directly to the 230 V AC mains power supply a mains isolator must be installed by the customer Wire the circuit according to th...

Страница 9: ...gh the supply air blower and enters the room as supply air Exhaust air blower depending on the equipment The exhaust air drawn in through the exhaust air blower and makes its way outside as outgoing a...

Страница 10: ...er failure the AEROMAT VT switches to the last level to be used Membrane key LED indicator Function LEDs do not light up Membrane key does not light up Blower level 0 unit is switched off Membrane key...

Страница 11: ...information concerning the design versions e g information about the filter The model plate is located beside the slider opening in the front profile see exemplary illustration SIEGENIA AUBI KG AEROMA...

Страница 12: ...D display lights up However we recommend replacing the filters at least every 12 months Always clean the G3 grit filter manually e g with a vacuum cleaner wash out using a grease dissolving cleaning a...

Страница 13: ...the power supply cable 2 Remove the front panel see page 12 3 Remove front profile insulation and filter 4 Remove the foam 5 Remove the supporting plate to do this press the top toward the interior o...

Страница 14: ...al noise at blower level 24 6 LpA approx 26 dB A Supply voltage 230 V Unit operating voltage 24 V Power consumption at blower level 1 approx 5 Watt Power consumption at blower level 2 approx 17 Watt P...

Страница 15: ...ed and the defect is due to the changes made Exclusion of liability The product and its components are subject to stringent quality controls As a result they function reliably and safely when used cor...

Страница 16: ...2811312 China Phone 86 316 5998198 France Phone 33 3 89618131 Germany Phone 49 271 39310 Great Britain Phone 44 2476 622000 Hungary Phone 36 76 500810 Italy Phone 39 02 9353601 Poland Phone 48 77 4477...

Отзывы: