![Siegenia AEROMAT VT RS1 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/siegenia/aeromat-vt-rs1/aeromat-vt-rs1_original-operating-instructions_1265134018.webp)
03.2021
18/20
H47.FENS082EN-01
AERO
Original operating instructions
AEROMAT VT RS1
15
Information requirements
according to EU Regulation
1253/2014
a
Producer
SIEGENIA
b
Model.identifier
AEROMAT VT RS1
c
Energy.consumption.(SEV);
Energy.efficiency.class.(SEC.class)
(according.to.climatic.zone.warm./.average./.cold)
−
0.8 kWh/(m².·.a);.F
−
8.4 kWh/(m².·.a);.F
−
21.8 kWh/(m².·.a);.D
d
Type
WLA./.ELA
e
Type.of.drive
Multi-stage.drive
f
Heat.recovery.system
―
g
Thermal.efficiency
―
h Maximum.flow.rate
62.m³/h
i
Electrical.input.power
21 W
j Noise level
34.dB.(A)
k Relative.air.flow.rate
43.4.m³/h
l
Relative.pressure.differential
―
m
Specific.input.power
0.16.W/(m³/h)
n
Control.factor./.control.typology
1 / 1.21
o
Highest.degree.of.inner.and.outer.leakage.rate
(inner./.outer.leakage)
―./.―
p
Mix rate (inner area / outer area)
―
q Instructions.for.replacing.filter
see.page.
r
Instructions.for.the.mounting.of.outside.air./.
exhaust.air.grilles
(for.one-directional.ventilation.units)
―
s
Instructions.for.dismantling
―
t
Pressure.fluctuation.sensitivity.of.the.air.flow
(at.+20.Pa.and.–20.Pa)
<.11.%
u
Air.tightness.between.inside.and.outside
4.6.m³/h