ORIGINAL OPERATING
INSTRUCTIONS
AERO
Sound absorbing ventilator.
AEROMAT VT RS1
Window systemsDoor systemsComfort systems
Страница 1: ...ORIGINAL OPERATING INSTRUCTIONS AERO Sound absorbing ventilator AEROMAT VT RS1 Window systems Door systems Comfort systems...
Страница 2: ......
Страница 3: ...ion without blowers 11 9 MEMBRANE KEY AND LED DISPLAY 11 9 1 Operating status 11 9 2 Filter replacement indicator 11 10 OPERATION 12 10 1 Adjustment of the blower level using the membrane key 12 10 2...
Страница 4: ...ion results from the weather grille preassembled in the factory Weather grille 911 HW installation position horizontal Weather grille 911 HW g concealed installation in the wall installation position...
Страница 5: ...it Risk of fatal injury from electric shock or fire To prevent personal injury or damage to property always comply with the following instructions work on a 230 V AC mains power supply may only be per...
Страница 6: ...elivery Unit item 1 Original operating instructions item 2 Quick start instructions SIEGENIA Comfort app item 3 Function Exhaust air fan or supply air fan Membrane key optional Grit filter ISO Coarse...
Страница 7: ...ition from which the outdoor air is drawn in must be selected in such way that any nearby emission sources have as little impact as possible on the quality of the air being drawn in The maximum permis...
Страница 8: ...installation of the exterior insulation or cladding According to the installation location it is thereforenecessarytoadheretheAEROMATVTRS1 at points where rain could permeate AEROMAT VT Film Adhesive...
Страница 9: ...ENIA aluminium mounting angles AEROMAT VT RS1 with 911 CW weather grille AEROMAT VT RS1 with 911 HW weather grille Dimension Meaning a Assembly area for bracket b Screw and drilling area e g for wall...
Страница 10: ...ty devices If the AEROMAT VT RS1 is connected directly to the 230 V AC mains power supply the customer must install a mains isolator 7 3 Wiring diagram series switch L1 N 18 17 16 15 13 11 10 9 8 7 14...
Страница 11: ...pressure differential As this happens the air normally flows into the room from outside The air flow into the room varies as the wind pressure changes with the weather With the optional internal elec...
Страница 12: ...ral times you can activate the required blower levels relaying Blower level 0 Blower level 1 Blower level 2 Power level 10 2 Adjustment of the blower level using the external switch You can activate t...
Страница 13: ...ains power supply switch off all poles of the feeder 11 1 Cleaning When cleaning the AEROMAT VT RS1 do not allow any liquid to get inside the unit Never use cleaning agents that are aggressive or cont...
Страница 14: ...rizontally The position of the components can deviate from the figure Be sure to note the arrangement of the internal parts for special models that do not correspond to the figure 1 2 3 4 1 Open the l...
Страница 15: ...6 Remove the foam 7 Remove the supporting plate to do this press the top toward the interior of the unit and pull out of the bottom 8 Open the transformer compartment and release the blower cable fro...
Страница 16: ...wer supply defective Have the supply voltage checked by a qualified electrician AEROMAT VT RS1 smart does not respond to smartphones tablets No WIFI connection to the router of the home network Restar...
Страница 17: ...vel 1 at blower level 2 at blower level 3 power level 3 W 7 W 21 W Supply voltage 230 V DC 50 Hz Unit operating voltage 24 V AC Protection class II Thermal protection in transformer Max permissible ar...
Страница 18: ...iency h Maximum flow rate 62 m h i Electrical input power 21 W j Noise level 34 dB A k Relative air flow rate 43 4 m h l Relative pressure differential m Specific input power 0 16 W m h n Control fact...
Страница 19: ...ctive EN 60335 1 2012 A11 2014 EN 62233 2008 c 2014 53 EC RED Directive c1 Electromagnetic compatibility EN 301489 1 V 1 9 2 EN 301 489 17 V 2 2 1 EN 61000 3 2 2014 EN 61000 3 3 2013 c2 Electrical saf...