The AEROMAT VT WRG 1000 may be installed in damp locations in protection class 2; however, the socket that is used
must be in at least protection class 3.
•
If the AEROMAT VT WRG 1000 is to be used in a room with a heating unit that draws air from the room, prior
authorisation must be obtained from the proper authorities, such as the officially appointed district chimney sweep.
Intended use requires that any combustion air lines and exhaust gas systems of solid fuel heating units must be able to be
shut off.
•
Only operate and/or store the AEROMAT VT WRG 1000 at temperatures between -15 °C and +40 °C.
•
Use the AEROMAT VT WRG 1000 only with genuine accessories from SIEGENIA.
•
Use the AEROMAT VT WRG 1000 only when it is in a technically sound condition. Do not modify the unit‘s components
in any way.
•
Ventilation openings must be kept free and must not be blocked by other equipment, furniture or objects.
•
If the AEROMAT VT WRG 1000 is fitted with filters, you must make sure that these cannot become the source of elements
that are odorous and harmful to health; this also includes regular inspection and replacement of filters.
Safety notices
•
This unit can be used by children aged 8 and above as well as by people with physical, sensory or mental difficulties or
with a lack of experience and knowledge as long as they are supervised or have been instructed in how to use the unit
safely and understand the resulting risks. Children must not play with the unit. Cleaning and user maintenance must not be
carried out by children without supervision.
•
Only insert the Euro plug of the network connection cable into a suitable 230-V AC mains power supply.
•
If the network connection cable is damaged, it may only be replaced by SIEGENIA, its customer service department or a
qualified electrician.
•
Work on a 230-V AC mains power supply may only be performed by a qualified electrician.
•
All work on the 230-V AC mains power supply must be carried out in compliance with the current German VDE
regulations (e.g. VDE 0100) and any relevant country-specific requirements.
•
All-pole safety isolation should be used when fitting the network connection cable on-site.
•
Should a solid object or any liquid get inside the unit, stop operation immediately and disconnect the
AEROMAT VT WRG 1000 from the mains power supply:
- Check whether the AEROMAT VT WRG 1000 has become damaged.
- Have the unit repaired by a specialist if necessary.