Siegenia AERO AEROMAT VT WRG 1000 Скачать руководство пользователя страница 1

A ssembly   I ns tru ctI o ns

AEROMAT VT WRG 1000.

Sound absorbing ventilator with heat recovery.

W i n d oW   h a r dWa r e

D o o r   h a r Dwa r e

S l i d i n g   d o o r   h a r dwa r e

V e n t i l at i o n   t e c h n o lo gy

b u i l d i n g   t e c h n o lo gy

V e n t i l at i o n   t e c h n o lo gy

Содержание AERO AEROMAT VT WRG 1000

Страница 1: ...embly Instructions AEROMAT VT WRG 1000 Sound absorbing ventilator with heat recovery Window hardware Door hardware Sliding door hardware Ventil ation technology building technology Ventil ation technology ...

Страница 2: ...OMAT VT WRG 1000 Assembly Instructions Last update 10 2014 Contents Target group of this documentation 3 Intended use 3 Safety notices 4 Installation 5 Mains supply 8 Technical specifications 9 Liability 10 ...

Страница 3: ...exterior windows walls of permanent structures in accord ance with our installation and design documents as well as the specifications of our assembly instructions and is only suit able for the ventilation of enclosed rooms The AEROMAT VT WRG 1000 must be installed in the intended installation position horizontal or vertical The intended in stallation position is based on the weather grille that i...

Страница 4: ...cludes regular inspection and replacement of filters Safety notices This unit can be used by children aged 8 and above as well as by people with physical sensory or mental difficulties or with a lack of experience and knowledge as long as they are supervised or have been instructed in how to use the unit safely and understand the resulting risks Children must not play with the unit Cleaning and us...

Страница 5: ...quality of the air being drawn in The maximum permissible area load is 1 000 kg per running metre of ventilator length Installation options Installation in the window sill Concealed installation in the win dow sill Concealed installation in the window sill with channel Installation in the window lintel Concealed installation in the win dow lintel Vertical installation next to the window AEROMAT VT...

Страница 6: ...adding Attention Depending on the installation location of the AEROMAT VT WRG 1000 it may be necessary to mask up with adhesive tape areas which may be exposed to rainfall Example Installation concealed in the wall with wall duct Example Installation concealed in the lintel foil adhesive tape AEROMAT VT exterior insulation adhesive tape AEROMAT VT adhesive tape foil adhesive tape exterior insulati...

Страница 7: ... the casing profiles with a rivet We recommend that you use SIEGENIA aluminium mounting brackets AEROMAT VT WRG 1000 with 911 CW weather grille AEROMAT VT WRG 1000 with 911 HW weather grille Dimension Meaning a Mounting area for bracket b Screw and drilling area e g for window plugs or mounting screws c Installation depth A Bracket 20 x 20 x 2 optional B Z profile optional C Stop profile optional ...

Страница 8: ...d electrician All work on the 230 V AC mains power supply must be carried out in compliance with the current German VDE regula tions e g VDE 0100 and any relevant country specific requirements Switch off or unscrew the circuit breakers Important If the AEROMAT VT WRG 1000 is connected directly to the 230 V AC mains power supply a mains isolator must be installed by the customer Wire the circuit ac...

Страница 9: ...evel 2 Approx 42 m3 h without filter Approx 36 m3 h with filter Heat recovery efficiency3 max 62 Internal noise at blower level 14 LpA ca 17 dB A Internal noise at blower level 24 LpA ca 34 dB A Supply voltage 230 V Unit operating voltage 24 V Power consumption at blower level 1 10 W Power consumption at blower level 2 21 W Protection class II Mains supply 230 V 50 Hz Circuit breaker Thermo fuse i...

Страница 10: ... its components are subject to stringent quality controls As a result they function reliably and safely when used correctly Our liability for consequential losses and or claims for damages is excluded except in the case of wilful mis conduct or gross negligence or where we are responsible for injury to life limb or health Strict liability under the German Product Liability Act Produkthaftungsgeset...

Страница 11: ......

Страница 12: ... 2811312 China Phone 86 316 5998198 France Phone 33 3 89618131 Germany Phone 49 271 39310 Great Britain Phone 44 2476 622000 Hungary Phone 36 76 500810 Italy Phone 39 02 9353601 Poland Phone 48 77 4477700 Russia Phone 7 495 7211762 South Korea Phone 82 31 7985590 Switzerland Phone 41 33 3461010 Turkey Phone 90 216 5934151 Ukraine Phone 380 44 4637979 You can find address details for our internatio...

Отзывы: