63
Modules
ELM 611-01
Electronic key reading module as a
contactless access control system
with LED function.
As reading unit of electronic keys or
cards for opening doors, gates etc.
Suitable for:
• “stand-alone” mode, a maximum
of 9 electronic keys or cards can be
used.
• in conjunction with entrance con
-
troller EC 602-… a maximum of 899
electronic keys or cards can be used.
Programming takes place using
PRI 602-… or PRI 602-… USB.
• in conjunction with door con
-
troller IP TCIP 603-… a maximum of
500 users possible (larger systems
on request).
Programming via web browser.
Operating voltage: 12 V AC
Operating current: 120 mA
Contact type: contact 24 V, 1 A
Protection system: IP 54
Ambient temperature:
–20 °C to +55 °C
Dimensions (mm) W x H x D:
99 x 99 x 27
COM 611-02
Code lock module as an input device
for the placement of door calls and
control functions in conjunction with
Access and the Siedle access control
system.
• in conjunction with entrance con
-
troller EC 602-… for setting control
function and access control codes.
Programming takes place using
PRI 602-… or PRI 602-… USB and
provided PRS 602-…
• in conjunction with door con
-
troller IP TCIP 603-… for setting
control function and access control
codes.
Programming via web browser
• Operation with call controller
RC 602-…, for programming codes
for door calls, a C button to delete
incorrect entries and a DR button for
direct door release. This door release
function can additionally be con
-
trolled by a time switch provided by
the user. An integrated LED can be
used via an external potential-free
contact as a status indication.
Operating voltage: 12 V AC
Operating current: max. 140 mA
Protection system: IP 54
Ambient temperature:
–20 °C to +55 °C
Dimensions (mm) W x H x D:
99 x 99 x 27
FPM 611-02
Fingerprint module as access control
system with function LED.
Suitable for:
• Stand-alone operation
• Operation with entrance controller
EC 602-…
Programming takes place using
PRI 602-… USB or PRI 602-… and
provided PRS 602-…
• Operation with door controller
TCIP 603-…
Programming by means of web
browser
Operating voltage: 12 V AC
Operating current: max. 250 mA
Contact type: contact 24 V, 2 A
Switching time: 3 sec
Protection system: IP 54
Ambient temperature:
–20 °C to +55 °C
Height of structure (mm): 17
Dimensions (mm) W x H x D:
99 x 99 x 43
1
2
3
4
5
6
7
8
9
F
0
C