Specification of the Digital Inputs and Outputs
sinudyn-36
Hardware Description 0360520xx
55
Operating Mode: Nut Setting
Connector
X3A Pin
Input
Possible Assignment
Description
5
Digital-In
1
No function
No function is executed.
1
Digital-In
2
No function
No function is executed.
Emergency stop
Stopping input (LOW active): The device is decelerated by setting
the reference speed value to zero. Afterwards the drive is held con-
trolled in position (drift-free).
Speed enable
Stopping input (LOW active): The reference speed value is internal-
ly set to zero. The speed controller is operated as proportional con-
troller.
3
Digital-In
3
Parameter set 1
Parameter set for nut runner start
Parameter set 1/2
Parameter set for nut runner start
2
Digital-In
4
No function
No function is executed.
Parameter set 2
Parameter set for nut runner start
6
Digital-In
5
No function
No function is executed.
4
Digital-In
6
Nut runner start
The controller is activated. The selected program is executed.
7
Digital-In
7
No function
No function is executed.
Parameter set 3
Parameter set for nut runner start
8
Digital-In
8
No function
No function is executed.
Parameter set 4
Parameter set for nut runner start
Содержание sinudyn-0360520 Series
Страница 7: ...Symbols 6 Symbols...
Страница 13: ...Safety Instructions and Application Advice 12 Safety Instructions Application Advice...
Страница 15: ...Unit Assembly Complying EMC 14 EMC...
Страница 53: ...Functional Description of the Connectors Interfaces 52 Hardware Description 0360520xx sinudyn 36...
Страница 59: ...Specification of the Digital Inputs and Outputs 58 Hardware Description 0360520xx sinudyn 36...
Страница 75: ...General Information Regarding the Wiring 74 Hardware Description 0360520xx...
Страница 93: ...Appendix Manufacturers 92 List of Manufacturers...