General Information

 

 WARNING

Risk of serious injuries and material damage

Any works regarding installation, initial operation and maintenance must be carried

out  by  trained  staff  only.Furthermore,  electricians  which  connect  feed-in  systems

must be approved by the local DSO (distribution system operator).

Trained staff, according to this fundamental safety instruction, are persons familiar

with the installation, mounting, initial and permanent operation of the product and

they  are  qualified  appropriately  for  the  work.  The  standards  DIN  VDE  0100  and

DIN  VDE  0110  as  well  as  the  national  accident  prevention  regulations  shall  be

considered!

When installing feed-in systems adhere to all applicable regulations, special safety

instructions and technical connection conditions of the local DSO.

 

 DANGER

Material may be damaged and persons be injured seriously:

when covers are removed illegally,

improper use

when either the installation or the operation is incorrect

Observe the corresponding notes and information in the product documentation of

your device.

 

 WARNING

Risk of injuries and material damage due to illegal modifications

Only change the settings of the device after having contacted SIEB & MEYER.

All Information and advice attached to the device, such as safety instructions or danger

warnings and technical data (type plate) are:

not to be removed

not to be damaged

to be kept readably (no covers, no paint over or the like)

W

Safety Instructions

0460123A/0480123A/0480123D -

9

2

Содержание 0460123A

Страница 1: ...0460123A 0480123A 0480123D CNC 46 00 CNC 48 00 compact and CNC 48 00 compact VS with USB connector for external PC Art No manual 10086500004 P TD 0000195 14 2017 01 04 SIEB MEYER W...

Страница 2: ...4131 203 0 Fax 49 4131 203 2000 support sieb meyer de http www sieb meyer de SIEB MEYER Shenzhen Trading Co Ltd Room 306 3rd Floor Building A1 Dongjiaotou Industrial Area Houhai Dadao Shekou Nanshan...

Страница 3: ...About this Manual 1 Safety Instructions 2 The CNC Modules With USB Connection 3 0480123A and 0480123D 4 0460123A 5 Software and Driver Installation 6 W Chapter Overview 0460123A 0480123A 0480123D 3...

Страница 4: ...Chapter Overview W 4 0460123A 0480123A 0480123D...

Страница 5: ...4 2 10 Standards and Regulations 15 3 The CNC Modules With USB Connection 17 3 1 Variants 17 3 2 Scope of Supply 17 3 2 1 Dongle 18 3 3 Function 18 3 4 Connection Principle 19 4 0480123A and 0480123D...

Страница 6: ...Content W 6 0460123A 0480123A 0480123D...

Страница 7: ...ymbol Risk of injury 3 Risk symbol Graphic representation of the source of risk Risk levels Risk Level Description Indicates an imminently hazardous situation which if not avoided will result in death...

Страница 8: ...Symbol Description LED indication LED on LED indication LED off LED indication LED flashes 1 3 Illustration of General Notices General notices are illustrated by the following symbols Symbol Descript...

Страница 9: ...ed appropriately for the work The standards DIN VDE 0100 and DIN VDE 0110 as well as the national accident prevention regulations shall be considered When installing feed in systems adhere to all appl...

Страница 10: ...60947 and DIN EN 61800 5 1 are applied consequently Technical data and the connection specification can be found in the respective product documents Line filters If adequate interference suppression...

Страница 11: ...or the humidity should be prevented Avoid stacking of the devices during transport and storage The maximum storage period is 2 years Electrolytic capacitors produce high leakage currents when a voltag...

Страница 12: ...he temperature should be prevented Make sure that the aeration elements are free and open so that the air circulation is not restricted 2 5 Electrical Connection DANGER Risk of serious injuries due to...

Страница 13: ...y converters Prevent cable loops Therefore the units must only be connected to earth at the provided PE connection for the mains supply line and the racks only at the provided earth screw DANGER Conne...

Страница 14: ...n of the use of hazardous substances in electrical and electronic equipment SIEB MEYER products do not exceed the limits of the directive 2011 65 EU for hazardous substances SIEB MEYER products labele...

Страница 15: ...from his duty to check the programmed values for correctness 2 10 Standards and Regulations SIEB MEYER devices comply with the following standards and directives Low Voltage Directive 2014 35 EU Mach...

Страница 16: ...Safety Instructions W 16 0460123A 0480123A 0480123D 2...

Страница 17: ...s the components delivered for the device Scope of Supply Supply as retrofit CNC 48 00 compact SIEB MEYER article number 0480123A CNC 48 00 module consisting of CPU logic card 048010012 USB ISA adapte...

Страница 18: ...ies on machine controls Previously delivered industrial PCs can not meet these requirements anymore Another problem is that only small amounts of PC mainboards are still available for exchange of defe...

Страница 19: ...C module 0480123A CNC 48 00 compact VS CNC module 0480123D CNC 46 00 CNC module 0460123A 3 4 Connection Principle The following figure shows the connection principle of aCNC module with USB connec tio...

Страница 20: ...The CNC Modules With USB Connection W 20 0460123A 0480123A 0480123D 3...

Страница 21: ...g 2 Front view of the CNC modules 0480123A and 0480123D 1 0480123x Number of the CNC module with USB connector x module variant 0480123A CNC 48 00 compact 0480123D CNC 48 00 compact VS 2 LED indicatio...

Страница 22: ...4 Green 5 V 5 V voltage available L5 Without function L6 Green CPU RUN CPU runs L7 Green USB RUN Data transmission via USB 480 Mbit s Data transmission via USB 12 Mbit s L8 Green PC DATA Data transmis...

Страница 23: ...nector 5 1 View Fig 3 Front view of the CNC module 0460123A 1 0460123A Number of the CNC module with USB connector 2 LED indications status indications 3 USB connection type B square Connection to the...

Страница 24: ...ation L4 Green 5 V 5 V voltage available L5 Without function L6 Green CPU RUN CPU runs L7 Green USB RUN Data transmission via USB 480 Mbit s Data transmission via USB 12 Mbit s L8 Green PC DATA Data t...

Страница 25: ...he following operating systems Windows 7 only 32 bit version Windows Vista only 32 bit version Windows XP only 32 bits version Windows 10 only 32 bit version Error message in Windows 7 Ultimate If an...

Страница 26: ...f you install a wrong software version an error message will appear on the screen To find out which CPU card is installed in your CNC look at the layout of the CPU card for example 46 01 0001 48 01 00...

Страница 27: ...operability of the CNC This hardware upgrade is mandatory for machines with 5 or more Z axes if not available already The following window appears after the installation has been completed Activate t...

Страница 28: ...start the driver instal lation Click on Start Control Panel Device Installation Setup Activate the following options No let me choose what to do Install driver software from Windows update if not fou...

Страница 29: ...SB Driver Click on Finish to finish the installation of the USB driver Overwrite the file siebmeye ini in the directory C sm_wprog with the original file of the old system the backup file created befo...

Страница 30: ...Software and Driver Installation W 30 0460123A 0480123A 0480123D 6...

Отзывы: