7
Stabilizer Operation and User guide
version 2950-4 - 2018
Alarms and System monitoring
ALARM SETTINGS
1.
Turn monitoring of fins On or Off.
Light indicator (green if on) shows what is activated.
2.
Turn monitoring of hydraulic system On or Off,
Light indicator (green if on) shows what is activated.
3.
Turn monitoring of Dump valve On or Off,
Must be off if no dump valve present. Light indicator (green if
on) shows what is activated.
4.
Turn monitoring of Dual lock valve On or Off. Light indicator (green if on) shows what is activated.
5.
Goes to «ALARM LIST» page (K)
6.
Resets the alarm history (deletes it)
Only to be done in trouble free systems by authorized service personell
7.
Goes back to «Setup» menu
PANEL
ALARMS / SYSTEM MONITORING
The stabilizer system is equipped with several internal monitoring func-
tions to ensure safe operation of the system.
This includes monitoring of the various valves electric operation, hy-
draulic pressure, level and temperatures as well as internal monitoring
of the electronics.
If an ALARM occurs, the system will automatically center and lock the
fins and shut down operation so to ensure that it can not actively do
anythying wrong. However, with some faults, for example hydraulic
hose breakage/leaks, it might not be possible for the system to centre and lock the fins in which case you must
proceed with special caution as described later.
If you get an alarm - this shows up on your control panel.
Press the “SHOW ALARMS” button, and this will take you to the alarms page which shows you what the
system is alarming for.
There, you can “ACKNOWLEDGE ALARM” and the system will then try to re-start.
If the problem persist by the alarm re-appearing the issue needs to be checked and rectified before the system
will work again - and you need to OPERATE THE BOAT WITH SPECIAL ATTENTION in case of some of
these alarms.
Please see the table on the next page for a quick reference to actions to be taken.
If in doubt of the meaning or explanation - Please make sure to contact a Side-Power service representative to
ensure safe operation of your boat and avoid further potential damage to your systems.
ALARM LIST
1.
Time stamp for when the alarm occured
2.
Alarm description. See alarm list page for explanation
3.
Scroll up and down in the alarm list if necessary!
4.
ACKNOWLEDGE ALARM IMPORTANT !
This MUST be pressed to enable the system to try to resume
operation. Should of course only be done after ensuring that
the reason for the alarm is no longer present
5.
Goes back to «Setup» menu (G)
Goes back to «Setup»
menu
(click with mouse to go
there)
Time stamp for
when the alarm
occured
Alarm description
See alarm list for explanation
ACKNOWLEDGE ALARM
IMPORTANT ! This
MUST
be pressed to
enable the system to try to resume operation
Should of course only be done after ensuring
that the reason for the alarm is no longer
present
Scroll up and down
in the alarm list if
necessary!
1
2
3
4
5
1
2
3
4
5
6
7