Low
temperature
High temperature
Hot water
Outdoor air intake
Air exchanger
Air exchanger
Compressor
Compressor
Expansion
valve
Expansion
valve
Hydrothermal
exchanger
Hydrothermal
exchanger
Cold water
Water tank
Water tank
2.5 Dynamic cycle flow heating system
Your Solarstream has a dynamic cycle flow heating system that systematically cycles all of the
tank water through the heat exchanger to leave no cold spots so that all of the hot tank water
can be delivered. The superheated compressed gas circulates through a double layered,
outside coil whilst the tank water circulates through an inside coil. The heat from the outside
coil is transferred to the inside coil then circulated back into the tank. New cold water is
extracted from the bottom of the tank then cycled dynamically through the heat exchanger
until the controller picks up the signal from the tank sensor to stop heating. The advantages
of this method are: heating efficiency, stable hot water without over heating the top or under
heating at the bottom of the tank and all of the tank water will be heated.
2.4 Installation overview
To install your Solarstream, site the unit
and
ensure it will remain in a vertical position throughout its usable life and not lean over due to
possible erosion of soil under the plinth, or such risk. Adhere to the relevant plumbing
regulations in regard to the water heater installation. We recommend fixing the tank to the
adjacent wall as an added safety precaution. Use only quality plumbing components such as
those supplied in the Siddons QIK kit. Connect the water supply. Refer Section 4 for details.
Plug in the 15 Amp power lead to a 15 Amp outlet or ask your electrician to hard wire into an
off peak or Smart meter. Your Solarstream will provide reliable 60 degree hot water for many
years.
vertically on a concrete plinth without leaning
4
2.6 Model Nomenclature
MA HR W S -
- Z A B - 27 0 (
)
Source medium
MA: Air source
MW: Ground source
Function of the unit
HR: heating
Energy exchange medium
A: Refrigerant
W: Water
Z: Integrated type
W: Split type(indoor unit )
A: coil heating
B: circulating heating
A: Horizontal fan direction
B: Upward fan direction
C: Double air duct type
Design alternative serial number
The figure represents the horse power of unit
eg: 010 means 1 horse power
Tank capacity
270: 270L
S: with solar
(Without solar omitted)
SIDDONS
AIR TO WATER HEAT PUMP WATER HEATER
AIR TO WATER HEAT PUMP WATER HEATER
Содержание MAHRW010ZAB-270