9
Maintenance
SICK sensors are maintenance-free.
We recommend doing the following regularly:
•
Clean the external lens surfaces
•
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
10
Techni
cal
data
WT23-2Xxx4x
WT23-2P/Nxx2x WT23-2Sxx2x
WTE23-2
Sensing range
100 ... 800 mm
100 ... 1000 mm 100 ... 1000 mm 300 ... 2000 mm
Sensing range max.
50 ... 800 mm
1)
50 ... 1000 mm
1)
50 ... 1000 mm
1)
50 ... 2300 mm
1)
Light spot diameter/distance
30 mm / 800
mm
50 mm / 800
mm
50 mm / 800
mm
160 mm / 2000
mm
Supply voltage V
S
DC 10 ... 30 V
2)
DC 10 ... 30 V
2)
AC 90 ... 250 V
3)
DC 10 ... 30 V
2)
Output current I
max.
≤ 100 mA
≤ 100 mA
≤ 100 mA
Switching current (switching voltage)
3 A @ AC 250 V /
or DC 24 V
4)
Max. switching frequency
200 Hz
5)
200 Hz
5)
10 Hz
5)
200 Hz
5)
Max. response time
≤ 2.5 ms
6)
≤ 2.5 ms
6)
≤ 10 ms
6)
≤ 2.5 ms
6)
Enclosure rating
IP 65
IP 65
IP 65
IP 65
Protection class
II
7)
II
7)
II
8)
II
7)
Circuit protection
A,B,C,D
9)
A,B,C,D
9)
A,C
9)
A,B,C,D
9)
Ambient operating temperature
-25 ... +60 °C
-25 ... +60 °C
-25 ... +60 °C
-25 ... +60 °C
1)
Object with 90 % remission (based on standard
white DIN 5033)
2)
Limit value: operation in short-circuit protection
mains max. 8 A; residual ripple max. 5 Vss
3)
Limit values
4)
Usage category to EN 60947-1 AC-15, DC-13
5)
With light / dark ratio 1:1
6)
Signal transit time with resistive load
7)
Reference voltage DC 50 V
8)
Rated voltage AC 250 V, overvoltage category 2
9)
A = UV-connections reverse polarity protected
C = Interference suppression
MAINTENANCE
9
8015974.YVM5 | SICK
Subject to change without notice
7
WT
B
23-2
Xxx6x
300 ...
11
00 mm
1)
10
0 ...
11
00 mm
1)
1
2
mm /
800
mm
DC 10 ... 30 V
2)
≤ 100 mA
200 Hz
5)
≤ 2.5 ms
6)
IP 6
7
II
7)
A,B,C,D
9)
-
30
... +60 °C
B = inputs and outputs reverse-polarity protected
D
=
outputs overcurrent and short-circuit
protected