![SICK WI180C-PNS01 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/sick/wi180c-pns01/wi180c-pns01_operating-instruction_1264189021.webp)
Description
Value
Sensitivity to vibrations
IEC 60068, 10 – 55 Hz
Shock resistance
IEC 60068, 500 m/s² (~50 g)
Housing material
Polycarbonate
Dimensions (HxWxD) in
mm
39 x 102.35 x 36.8
1
Valid, if WI180C-PNS01 is connected via internal system bus with modules which fullfill IP54
Environmental parameters
Table 14: Environmental parameters
Description
Value
Air humidity
(operation/storage)
35 – 85 % relative humidity
Temperature range
(storage)
-40 – +70 °C
Temperature range
(Operation, ≤3 connected
devices)
-25 – +55 °C
1
Temperature range
(Operation, ≤8 connected
devices)
-25 – +50 °C
1
Temperature range
(Operation, ≤16 connected
devices)
-25 – +45 °C
1
1
Temperature ranges valid if no output current on connected devices
10.3
Ordering information, accessories
Table 15: Ordering information
Type
Description
Part number
YF8U14-020VA3XLEAX
Female connector, M8, 4-pin,
straight, 2 m cable
2095888
YF8U14-050VA3XLEAX
Female connector, M8, 4-pin,
straight, 5 m cable
2095889
YG8U14-020VA3XLEAX
Female connector, M8, 4-pin, angled,
2 m cable
2095962
YG8U14-050VA3XLEAX
Female connector, M8, 4-pin, angled,
5 m cable
2095963
SSL-1204-G02MZ90
Male connector, M12, 4-pin, straight,
D-coded, 2 m cable
6048241
TECHNICAL DATA
10
8022756/2018-08-08 | SICK
O P E R A T I N G I N S T R U C T I O N | WI180C-PNS01
21
Subject to change without notice