4
Mounting
1
2
3
6
5
4
Figure 2: Mounting
1
Base screws
2
Optional base screws
3
Flank screws
4
No deformation!
5
Flank screws are loose
6
Base screws are tight
Normal mounting is recommended to be done with the base screws.
To obtain better stability the optional base screws can be used.
NOTE
It is important that the mounting surface is flat.
NOTE
To obtain full vibration resistance all 6 screws are to be used.
This requires an absolute flat mounting surface to avoid twisting of the sensor.
The reference points of the respective fixing holes to the crossed light beam can be
seen in the dimensional drawing,
5
Electrical installation
The sensors must be connected in a voltage-free state (U
V
= 0 V). The following informa‐
tion must be observed, depending on the connection type:
–
Plug connection
Only apply voltage/switch on the voltage supply (U
V
> 0 V) once all electrical connec‐
tions have been established.