Mounting variant
Length of protective
pipe
Operating tempera‐
ture range
Accessories
1
With top and bot‐
tom bracket
285 mm -1035 mm
–20 °C … +55 °C
4x 2023708 or 4x
2026850
2
With top and bot‐
tom bracket and sup‐
port brackets
1185 mm - 335 mm
–20 °C … +55 °C
4x 2023708 or 4x
2026850 and 2x
2026849
1485 mm -
2535 mm
0 °C … +35 °C
4x 2023708 or 4x
2026850 and 2x
2026849
3
With a bracket
and support brackets
1485 mm -
2535 mm
–20 °C … +55 °C
1 x 2023708 or
2026850 and
2026849
6
Electrical installation
When connecting with an extension cable, observe the following note:
NOTE
For 8-pole sensor-actuator cables, the wire colors are not standardized.
Therefore, please observe the pin assignment of the sensor and the cable
in the respective data sheet.
+(L+)
Sync A
-
(M)
Sync B
TEST
1
2
3
4
5
Sender
Receiver
+(L+)
-
(M)
Sync B
Q
1
/C
3
Q
2
/In
1
3
1
2
3
4
5
6
7
8
Sync A
4
1
2
5
3
6
5
1
4
3
2
8
7
PK
VT
OG
BN
WH
BU
BK
GY
BN
WH
BU
BK
GY
PK
BU
RD
WH
BN
GN
YE
GY
1
2
3
4
5
6
7
8
IP69K connecting cable
1
2
1
Valid for:
YF2AP8-250PA4XLEAX (2116447),
YF2AP8-020PA4XLEAX (2111888)
2
Observe the pin assignment of the sensor and the cable in the respec‐
tive data sheet
3
Depending on type
7
Accessories
Part number
Type
Description
2023708
BEF-2SMMEAES4 4 pieces, holder stainless steel, swiveling, clamp in one
piece and removable
2026850
BEF-2SMMVAES4 4 pieces, holder stainless steel, swiveling, clamp in two
parts
2026849
BEF-2AAADES2
2 pieces, stainless steel support bracket
8
Cleaning
IP69K = Protection against water at high pressure / steam cleaning.
Clean the protective pipe at regular intervals. Observe the following points while
cleaning:
•
Do not use any corrosive cleaning agents.
•
Do not use any abrasive cleaning agents.
•
You can reduce this effect by using an anti-static plastic cleaner (part num‐
ber 5600006) and a SICK lens cloth (part number 4003353).
Proceed as follows when cleaning the protective pipe:
1.
Remove any dirt on the protective pipe with plenty of water.
2.
Remove any leftover water on the protective pipe.
3.
Dry the protective pipe with a clean, lint-free cloth.
9
Maintenance
SICK devices are maintenance-free.
We recommend cleaning the device and checking screwed and plugged connec‐
tions at regular intervals.
No modifications may be made to devices.
10 Disposal
The device must be disposed of according to the applicable country-specific
regulations. Efforts should be made during the disposal process to recycle the
constituent materials (particularly precious metals).
11 IPG69K protective pipe technical data
The protective pipe reduces the operating range of the light grid MLG-2 as speci‐
fied in the following table.
Operating range [m]
Sensing range with protective pipe [m]
8,5
6,3
5
3,75
Operating range [m]
Sensing range with protective pipe [m]
2 (only MLG-2 with 2.5 mm beam distance)
1,5
Maximum monitoring height 2,400 mm.
Description
Value
Enclosure rating
IP 69K
Material
Protective pipe: PMMA Plexiglas XT Food Contact DoC
Pipe: polypropylene stainless steel 1.4404
Pressure compensation element: VA 1.4305
End caps: stainless steel 1.4404
Cable gland: stainless steel V4A 1.4404 DIN EN 1672-2
Ambient temperature
–20 °C … +55 °C
12 IPG69K Dimensions protective pipe and mounting variants
1
2
3
2
5
3
4
5
6
9
ß
9
ß
8
7
Ø
5
0
(1
.9
7
)
Ø
3
0
.5
(1
.2
)
Ø
5
0
(1
.9
7
)
Ø
3
0
.5
(1
.2
)
Ø
5
0
(1
.9
7
)
2
3
(0
.9
1
)
Ø
5
0
(1
.9
7
)
2
3
(0
.9
1
)
392 ±10
(15.45 ±0.39)
M
1
2
5
P
.
M
1
2
5
P
./
8
P
.
56
(2.2)
A
B
27 (1.06)
2
(0.08)
Distance A
Distance B
2,5-mm-grid
A = 94.25 mm
2,5-mm-grid
B = 84.7 mm
5-mm-grid
A = 9.55 mm
5-mm-grid
B = 83.6 mm
10-mm-grid
A = 100.5 mm
10-mm-grid
B = 83.6 mm
20-mm-grid
A = 100.5 mm/
110.5 mm
1
20-mm-grid
B = 83.6 mm
25-mm-grid
A = 115.5 mm
25-mm-grid
B = 83.6 mm
30-mm-grid
A = 120.5 mm
30-mm-grid
B = 83.6 mm
50-mm-grid
A = 140.5 mm
50-mm-grid
B = 83.6 mm
1
MLG20x-xx40: 100.5 mm
MLG20x-xx80: 110. mm
8025069.1CU6 / 07.09.2021/de, en