Figure 2: Opening the sensor
Figure 3: Electrical connection
Only apply voltage/switch on the voltage supply (U
V
> 0 V) once all electrical connec‐
tions have been established.
Explanation of the connection diagram (Tables 2-7) which are divided up into DC and
AC/DC devices:
Alarm = alarm output (see
n. c. = not connected
NC = normally closed
NO = normally open
Q /
Q
= switching outputs
TE / Test = test input (see
5.1
DC
DC: 10 ... 30 V DC,
Table 2: DC
WT24-2
B3x3
B2x0
V2x0
B4x0
V5x0
V510S15 B410S25
1
+ (L+)
+ (L+)
+ (L+)
+ (L+)
+ (L+)
+ (L+)
+ (L+)
2
- (M)
- (M)
- (M)
Test
Test
Alarm
n. c.
3
Q/
Q
-
Alarm
- (M)
- (M)
- (M)
- (M)
4
-
Q/
Q
Q/
Q
Q/
Q
Q/
Q
Q/
Q
Q/
Q
5
-
Test
Test
-
Alarm
Test
-
1
2
3
4
5
0.14 ...
1.5 mm
2
1
2
3
4
5
0.14 ...
1.5 mm
2
1
2
4
3
1
2
5
4
3
1
2
5
4
3
1
2
4
3
ELECTRICAL INSTALLATION
5
8008784.Z474 | SICK
Subject to change without notice