3
SYSTEM DESCRIPTION
22
8026365/V1-0/2022-03|SICK
S U P P L E M E N T A R Y O P E R A T I N G I N S T R U C T I O N S | VMS4200-x/5200-x MID
Subject to change without notice
3.2.6
Expanding the system with a reading station
Fig.10: Expanding the system with a reading station
Legend
1
VMS4200-x / 5200-x MID
2
Reading systems
3
CAN bus
•
Expansion of the VMS4200-x / 5200-x MID multi-dimensional measurement system
with a reading station.
•
Depending on the application, this station can consist of scanners, cameras,
application-specific trigger elements and/or a combination of these components in
any desired arrangement.
•
Allows automated object identification using bar codes.
•
Streamlines process automation.
NOTE!
The multi-dimensional measurement system can also supply the focus
information for the connected camera systems.
•
The devices are connected to the multi-dimensional measurement system via the
CAN bus of the SIM2000-2 Prime controller.
•
The SIM2000-2 Prime controller links the acquired identification data with the
dimension values calculated by the VMS4200-x/5200-x MID.
•
Identification data and dimension values are output together to the higher-level
system.
Properties
Function
Connection