Annex
11.2.1
Input signals from the EFI connection to the (F)PLC
EFI1 address
2.7
2.6
2.5
2.4
2.3
2.2
2.1
2.0
EFI2 address
4.7
4.6
4.5
4.4
4.3
4.2
4.1
4.0
C4000 Standard/Advanced
Reset
required
Reset
Status
message
output
(ADO)
Reserved
Reserved
Reserved
Reserved
OSSD
(Switching
output)
green
M4000 Advanced
Reset
required
Reset
Status
message
output
(ADO)
Reserved
Additional
signal C1
or belt stop
Muting
lamp
off/on
Muting
status
OSSD
(Switching
output)
green
M4000 Advanced with UE403
Reset
required
Reset
Status
message
output
(ADO)
Reserved
Additional
signal C1
or belt stop
Muting
lamp
off/on
Muting
status
OSSD
(Switching
output)
green
S3000
Reset
required
Reset
Simultaneous monitoring
range
9)
Used monitoring range
Warning
field free
OSSD
(Switching
output)
green
Warning
field free
10)
Protective
field free
Warning
field free
Protective
field free
S300
Reset
required
Reset
Reserved
Reserved
Used monitoring range
Warning
field free
OSSD
(Switching
output)
green
Warning
field free
Protective
field free
EFI1 address
3.7
3.6
3.5
3.4
3.3
3.2
3.1
3.0
EFI2 address
5.7
5.6
5.5
5.4
5.3
5.2
5.1
5.0
C4000 Standard/Advanced
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
M4000 Advanced
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
M4000 Advanced with UE404
Override
lamp
Reset/
Override
Additional
signal C1/
belt stop/
Override
Reserved
Status of the muting sensors on UE403
B2
B1
A2
A1
S3000
Status of the monitoring case inputs at the S3000
In D2
In D1
In C2
In C1
In B2
In B1
In A2
In A1
S300
Status of the monitoring case inputs at the S300
Reserved
Reserved
Reserved
Reserved
In B2
In B1
In A2
In A1
Tab. 17: Process image of the input signals from the EFI connection to the (F)PLC
9)
Warning:
The return value depends on the firmware version of the used S3000:
S3000 firmware
version
Return value
Simultaneously monitored area
defined
Simultaneously monitored area not
defined
Controller
2.26 and
interface
1.00
Status of the protective field/warning
field
Permanently 1 (protective
field/warning field free)
Controllers < 2.26 and
Interface < 1.00
Permanently 0 (protective
field/warning field free)
10)
Warning, this information is only valid for UE4740 and S3000 using S3000 controller software version
< 2.26 and S3000 interface software version < 1.00:
Only evaluate this bit in the FPLC together with the passivation state of the UE4740!
Reason: The bit logic
is inverted. The bit has the value 1 when a dangerous state has been recognised. The bit has the value 0
when no dangerous state has been determined. However, the bit can assume the value 0 due to faulty
communication. The passivation state of the UE4100 must therefore be monitored additionally (for example
at Siemens Step 7: PASS_OUT variable in the data block F-Periphery DB).