Chapter
12
Operating Instructions
UE4155
72
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
8010178/TF82/2010-03-05
Subject to change without notice
Annex
12.3.3
Diagnostics data of the field-signal connections
Address
16.7
16.6
16.5
16.4
16.3
16.2
16.1
16.0
T
Out
B
In B
T
Out
A
In A
Field-signal input 1
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Address
17.7
17.6
17.5
17.4
17.3
17.2
17.1
17.0
T
Out
B
In B
T
Out
A
In A
Field-signal input 2
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Address
18.7
18.6
18.5
18.4
18.3
18.2
18.1
18.0
T
Out
B
In B
T
Out
A
In A
Field-signal input 3
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Address
19.7
19.6
19.5
19.4
19.3
19.2
19.1
19.0
T
Out
B
In B
T
Out
A
In A
Field-signal input 4
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Address
20.7
20.6
20.5
20.4
20.3
20.2
20.1
20.0
T
Out
B
In B
T
Out
A
In A
Field-signal input 5
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Address
21.7
21.6
21.5
21.4
21.3
21.2
21.1
21.0
T
Out
B
In B
T
Out
A
In A
Field-signal input 6
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Address
22.7
22.6
22.5
22.4
22.3
22.2
22.1
22.0
T
Out
B
In B
T
Out
A
In A
Field-signal input 7
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Address
23.7
23.6
23.5
23.4
23.3
23.2
23.1
23.0
T
Out
B
In B
T
Out
A
In A
Field-signal input 8
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Overload
Reserved
Input
incorrectly
configured
Test-error at
the input
Address
24.7
24.6
24.5
24.4
24.3
24.2
24.1
24.0
Discrepancy time overflow
Field-signal input …
Diagnostics
8
7
6
5
4
3
2
1
Address
25.7
25.6
25.5
25.4
25.3
25.2
25.1
25.0
Diagnostics
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Tab. 36: Diagnostics data of the field-signal connections
16)
In the case of the set discrepancy-time overrun of the diagnosis bit, the status bits for In A and In B are
assigned failsafe values.