10.3
Performance
Operating range
UC40-11
2
11x: 65 mm ... 350 mm
UC40-11
3
11x: 200 mm ... 1,300 mm
UC40-11
4
11x: 350 mm ... 3,400 mm
Limiting range
UC40-11
2
11x: 600 mm
UC40-11
3
11x: 2,000 mm
UC40-11
4
11x: 5,000 mm
Measuring object
Natural objects
Resolution
UC40-11
2
11x: ≥ 0.1 mm
UC40-11
3
11x: ≥ 1 mm
UC40-11
4
11x: ≥ 1 mm
Repeatability
± 0.15%
1)
Accuracy
± 1%
2)3)
Temperature compen‐
sation
Response time
4)
UC40-11
2
11x: 64 ms
UC40-11
3
11x: 96 ms
UC40-11
4
11x: 160 ms
Switching frequency
UC40-11
2
11x: 10 Hz
UC40-11
3
11x: 7 Hz
UC40-11
4
11x: 4 Hz
Output time
UC40-11
2
11x: 16 ms
UC40-11
3
11x: 24 ms
UC40-11
4
11x: 41.6 ms
Ultrasonic frequency
(typical)
UC40-11
2
11x: 400 kHz
UC40-11
3
11x: 200 kHz
UC40-11
4
11x: 120 kHz
Detection range (typi‐
cal)
Additional function
Adjustable switching point modes: switching point (Single Point Mode) / switching window (Window
Mode) / background (Window Mode 8%), teachable digital output, parameterizable digital output,
invertible digital output, adjustable switch-on delay digital output, teachable analog output, parame‐
terizable analog output, invertible analog output, automatic switching between current and voltage
output, analog output switchable to second digital output, synchronization of up to 50 sensors,
multiplexing: no mutual interference of up to 50 sensors, adjustable measurement filters: measured
value filter / filter strength / foreground suppression / detection range / sensitivity and sound lobe /
false echo suppression, teach-in buttons (can be deactivated), reset to factory settings
1)
Relative to the current measured value, minimum value ≥ resolution.
2)
Relative to the current measured value.
3)
Temperature compensation can be switched off, not temperature compensated: 0.17% / K.
4)
Subsequent smoothing of the analog output may increase the response time by up to 200% in some applications.
10.4
Interfaces
IO-Link
IO-Link V1.1
Function: Process data, configuration, diagnostics, data storage
Digital output
Quantity: 1
Type: Push-pull: PNP/NPN
1)
Maximum output current I
A
: ≤ 100 mA
TECHNICAL DATA
10
8027772//2022-08-11 | SICK
O P E R A T I N G I N S T R U C T I O N S | UC40
39