![SICK STR1 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/sick/str1/str1_operating-instructions-manual_1264703037.webp)
Inputs
Switching current
ON state
OFF state
≤ 5 mA
0 mA
Switching voltage
ON state
OFF state
21 V DC ... 24 V DC
≤ 2 V DC
Table 24: Outputs
Outputs
2 OSSDs (OSSD1 and OSSD2)
2 x PNP, max. 100 mA, short-circuit protected
and overload-proof
Application diagnostic output (Aux)
50 mA max, short-circuit protected
Switching current
ON state
OFF state
≤ 100 mA
< 500 µA
Switching voltage
ON state
OFF state
21 V DC ... 24 V DC
0 V DC ... 2 V DC
Table 25: Ambient data
Ambient data
Enclosure rating
IP67 (IEC 60529)
IPX9K (ISO 20653)
1)
Ambient operating temperature
–30 °C … +70 °C
2)
Storage temperature
–30 °C … +70 °C
Vibration resistance
1 mm / 10 Hz ... 55 Hz (IEC 60068-2-6)
Shock resistance
30 g, 11 ms (IEC 60068-2-27)
EMC
In accordance with IEC/EN 61326-3-1, IEC/
EN 60947-5-2, IEC/EN 60947-5-3 and
EN 300330 V2.1.1
1)
The cables of the safety switches must not be exposed to high pressure or strong water jets during clean‐
ing.
2)
Only applies for safety switches whose serial numbers begin with number series 1825**** or higher. For
safety switches whose serial numbers deviate from this, an ambient operating temperature of
-10 °C … +70 °C applies.
The serial number is displayed on the safety switch over the data matrix code.
TECHNICAL DATA
11
8018754/12IU/2020-01-30 | SICK
O P E R A T I N G I N S T R U C T I O N S | STR1
37
Subject to change without notice