© SICK AG • Presence Detection • Subject to change without notice • 8017387
11
Operating instructions IO-Link USB Master SiLink2 Master
Electrical Connection
5 Electrical Connection
5.1
Safety
Incorrect Supply Voltage
WARNING!
Device damage due to incorrect supply voltage!
Incorrect supply voltage can cause damage to the device.
Therefore:
• If necessary, only operate the SiLink2 Master using the
supplied wall plug.
5.2
Electrical Connection of SiLink2 Master
2
USB
IO-Link
PC
SiLink2 Master
IO-Link Device
1
Fig. 3: Electrical Connection of SiLink2 Master
1 USB cable
2 Sensor cable
1. Ensure power supply is not connected.
2. Connect the PC to the USB Mini B female connector of the SiLink2
Master using the supplied USB cable.
3. Connect IO-Link device to the M12 male connector of the SiLink Master
using a sensor cable. A 3-pole or 4-pole cable may be used as the
sensor cable.
NOTE!
If the power requirement of the IO-Link device is
> 80 mA, connect the supplied wall plug to the DC 24 V
female connector of the SiLink Master and connect the
wall plug to the supply voltage.