![SICK S3000 Expert Скачать руководство пользователя страница 80](http://html.mh-extra.com/html/sick/s3000-expert/s3000-expert_operating-instructions-manual_1264650080.webp)
Further topics
•
"Pre-assembled system plug", page 80
•
•
"Connecting cables for self-assembly", page 159
6.4
Pre-assembled system plug
SX0A-B0905G
•
For S3000 Standard and Remote
•
With 9 unshielded wires
•
Cable connection at the rear
•
5 m long
SX0A-B0905B, SX0A-B0910B, SX0A-B0920B
•
For S3000 Standard and Remote
•
With 9 unshielded wires
•
Cable connection at the top
•
5, 10 or 20 m long
SX0A-B1305B, SX0A-B1310B, SX0A-B1320B
•
For S3000 Advanced
•
With 13 unshielded wires
•
Cable connection at the top
•
5, 10 or 20 m long
SX0A-B1305D, SX0A-B1310D
•
For S3000 Professional and S3000 Expert with static and dynamic inputs
•
With 13 unshielded wires
•
With 3 M12 cable entries for incremental encoders
•
Cable connection at the top
•
5 or 10 m long
SX0A-B1705B, SX0A-B1710B, SX0A-B1720B
•
For S3000 Professional and S3000 Expert with static inputs
•
With 17 unshielded wires
•
Cable connection at the top
•
5, 10 or 20 m long
Table 11: Pin assignment on pre-assembled system plugs
Pin Signal
Wire color
SX0A
-B0905G
SX0A
-B0905B
SX0A
-B0910B
SX0A
-B0920B
SX0A
-B1305B
SX0A
-B1310B
SX0A
-B1320B
SX0A
-B1305D
SX0A
-B1310D
SX0A
-B1705B
SX0A
-B1710B
SX0A
-B1720B
1
24 V DC
Brown
C
C
C
C
C
2
0 V DC
Blue
C
C
C
C
C
3
OSSD1
Gray
C
C
C
C
C
4
OSSD2
Pink
C
C
C
C
C
5
Red
C
C
C
C
C
6
Yellow
C
C
C
C
C
7
UNII/O1 / ERR
White/black
C
C
C
C
C
8
UNII/O2 /
RES_REQ
Red/blue
C
C
C
C
C
9
UNII/O3 / WF
White/brown
C
C
C
C
C
10 A1
White/red
C
C
C
11 A2
White/orange
C
C
C
6
ELECTRICAL INSTALLATION
80
O P E R A T I N G I N S T R U C T I O N S | S3000
8009942/ZA18/2019-11-14 | SICK
Subject to change without notice